Group 1 isolation signals?
-47" RPV
<= 840# when in Run
135-140% steam flow
195-200F steam chase temp
C-15 Group I isolation keylock in TRIP
What is isolated by a Group 1 signal?
MSIVs (inboards and outboards)
MSIV drains (MO-2073 and MO-2074)
Recirc Sample (CV-2790 and CV-2791)
Group 2 isolation signals?
+9" RPV level
1.84# Drywell press
What is isolated by a Group 2 signal?
RHR/SDC
TIPS
Atmosphere sampling
DW sumps
N2 purge
Group 2 partial isolation signals?
-47" RPV level
1.84# Drywell press
RB Rad level 26 mrem
FP Rad level 50 mrem
What is isolated by Group 2 partial?
Secondary containment
Starts SBGT
Starts EFT
Group 3 isolation signals?
-47" RPV level
1.84# Drywell press
460 gpm or -200 gpm for 10 sec
170F RWCU room temp
(SBLC)
What is isolated by a Group 3 signal?
RWCU
Recirc sample
Group 4 isolation signals?
300,000 lbm/hr for 4 sec
187.5F
100#
What is isolated by a Group 4 signal?
HPCI
Group 5 isolation signals?
44,434 lbm/hr for 5 sec
187.5F
60#
What is isolated by a Group 5 signal?
RCIC