Water stains along the junction of the foundation wall and the floor most likely indicate
drain tile problems
On the inspection report, 5F is?
trash compactor
What is the maximum overcurrent protection for #12 copper wire?
20 amps
What is the minimum wire size for 30 amps, both copper and aluminum?
10 copper and 8 aluminum
On the inspection report, what is 4A?
water supply and fixtures
What contributes to ice damming?
improper insulation and ventilation
What is the dead load?
The structure
What is the live load?
What you put into the structure
What is the clearance for closet lighting?
recessed lighting is 6 inches and enclosed is 12 inches
What is 3A on the inspection report?
Heating
For recessed lighting, what is the clearance to insulation?
6"
A thumping or rumbling noise heard while a gas water heater is firing indicates?
sediment in the tank
What does a collar tie or a collar beam do?
Gives rigidity to the rafters and prevents the walls from spreading
What is the minimum attic access opening?
18 X 24 unless there is mechanical equipment in there. Then it is 22 X 30
How many feet of clearance does the NEC require for the overhead service drop over driveways and yards?
12'
4 wires ( 3 hot and 1 neutral) indicates?
3 phase
3 wires ( 2 hot and 1 neutral) indicates?
240 volt
2 wires ( 1 hot and 1 neutral) indicates?
120 volt
What does the fireplace smokeshelf prevent?
downdrafts
What number do you divide the amount of square footage in crawl space by to determine the correct ventilation?
150
In areas of expansive soil, drainage from the roof to the ground surface must be at least how many feet from the foundation walls?
5'
3C on the inspection report is?
duct system, chases, and vents
An inspector does not have to check the _____ of a fireplace/chimney
draft
The purpose of the SOP adopted by TREC is to _____
establish the minimum level of inspection service
The maximum riser heighth on a staircase is ?
7 3/4"
At what point in an A/C cycle does the liquid turn to gas?
coming out of the evaporator coil
Asphalt shingles can be installed on roofs as low as 2:12 if _______
the roof is covered with two layers of non-perforated felt paper
What method of attic ventilation is considered to be the most effective?
combination of soffet vents and ridge vents
Name 4 types of roof systems
Mansard, Gable, Gambrel, Hip
Your hot water smells like rotten eggs. What would be one way to remove the odor?
replace the anode
How many bearing points does a truss have?
2
Most building codes allow ballusters or railings to be a maximum of how many inches apart?
4
What type of trap is legal under modern code?
P trap
How is horizontal cast iron pipe vulnerable?
sewer gas can eat through the top of the pipe
What is a symptom of a water logged pressure tank?
the pump runs constantly
Which type of plastic piping is blue-gray?
PB polybutylene
Repeated, visible sagging for a span of 24" in a roof is usually caused by?
thin plywood sheathing
What type of wall framing uses long studs that reach from the sill plate to the rafter using a plate to support second story joists?
balloon framing
Wood shingles should be spaced how far apart?
3/8 "
All residents must have one exit door that is a minimum of ___feet wide and ___ft__inches high.
3ft 6'8"
Weepholes must be spaced a maximum of how many inches apart?
33
attics that are equal to or greater than ____inches high and greater than ___square feet require access.
30 and 30
All doors require ____operation from interior
keyless
Hallways must be a minimum of ______inches wide
36
Skylight curbing must extend how many inches above the roof?
4"
True or false. Openings in crawl spaces must be screened or grated?
True
Bottom of the sill must be a minimum of ____inches to the ground
6"
What does a drip edge do?
Protects the parts below it. ( soffet, fascia)
On low sloping roofs, drains must be installed at all low points and secondary drains are required ____ inches above the low point of the roof.
2"
The hearth extension must be ___inches deep and ___inches to each side if the opening is greater than 6 feet
20 and 12
A copper to steel connection undergoes what kind of reaction?
electrolytic
The hearth extension is a minimum of ___inches deep and ___inches to each side if the opening is less than 6 feet
16 and 8
What causes water hammer?
Loose pipes, hydrostatic shock, or instantaneously closing valves
Bathrooms require at least a ___sq ft opening for natural ventilation or a _____fan to the outside
1 1/2 50 cfm
Openable windows equal to or greater than ___inches and with greater than a ____inch drop off must be a minimum of ____inches above the interior floor or be provided with a window guard.
4 72 24
Minimum working space in front of a water heater is ____inches.
30
All egress windows must have a minimum of a ____sq ft of opening
5.7
All garage receptacles must be _____ protected
GFCI
All bedroom receptacles must be ____protected
AFCI
Clearance for the disconnect at the A/C condenser is a minimum of ____inches wide and ____inches deep
30 and 36
The circuit minimum for the water heater must be ____% of the nameplate rating
125%
A 125 volt receptacle must be within how many feet of the furnace
25'
The dishwasher and the _____may not be on the same circuit
disposal
The disconnect at the A/C condenser must ALWAYS be ___ ____.
in sight
A receptacle is required behind a corner sink if space behind the sink is ______ deep
equal to or greater than 18"
Any receptacle serving a kitchen counter must be ______ protected
GFCI
There must be a minimum of __ small appliance circuits serving countertops
2
Hallways equal to or greater than ___feet long require a receptacle
10'
Any wall equal to or greater than ___ foot long in a habitable room requires a receptacle
2'
The landing at an exterior door can be one riser height below the threshold if ____
the door does not swing outward over the landing
The recommended slope of waste plumbing is
1/4" per foot
Headroom on stairways must be a minimum of
6'8"
Minimum pipe size for water service is
3/4 "
Clearance for toilets is
___ in front and ___ in side clearance
21 and 15
The laundry P trap should be how high off the floor?
6" to 18"
Each dwelling unit shall have at least one habitable room that has a minimum of ____ sq ft
120
What is the minimum size for a habitable room (not a kitchen)
70 sq ft
Panel boxes are allowed in ____ or ____
closets or bathrooms
The drip loop must be a minimum of ___ft off the ground
10
Service drop clearance above areas accessible only to pedestrians is
10'
Service drop clearance above residential property and driveways is
12'
service drop clearance above public streets and tractor trailer parking is
18'
service drop clearance above a roof with a slope of greater than 4:12 is
3'
Service drop clearance must be maintained past the roof edge for ___ft
3'
Service drop clearance above a roof that is used as a walkable deck is
10'
Service drop clearance should be how many feet below or to the sides of doors and openable windows
3'
Minimum heighth for a guardrail is
36"
What is the most common cause of leaking in flat roofs
parapet walls
What is the most durable roof covering
slate
When does a built up roof need flood coating
when tar paper is showing
Where is roof most likely to lead when re-roofing
at penetrations
On the inspection report, what is 5D
ranges, cooktops, and ovens
What is 5A on the inspection report?
dishwasher
If two gas appliances are in a single room,
they must each have their own shut off
What is 4D on the inspection report?
hydro-massage thereapy equipment
What is 3B on the inspection report?
cooling
An overcurrent device is another name for a
breaker
The two main components of an air cooled conditioning system are