-
4 ways to indicate 4
- Heat
- smoke
- heat rate of change
- light
-
What are the two catagories of detector circuits
-
What are 3 components of a fire detection system
- Test circuit
- detector circuit
- alarm circuit
-
What are the 2 pnuematic systems
-
3 maintenance items on a cont. loop system
- supported every 8-10 inches
- bend radius 3``
- No crushing , kinking, or chafing
-
what are the 3 types of of ssmoke detectors
- light refraction
- ionization
- solid state
-
what are 2 common extinguishing agents used in aircraft
-
What does a missing red disk indicate
Over temp pressure discharge
-
What does a missing yellow disc indicate
Shows a system discharge
-
what is a HRD use for suppressant
Halon 1301
-
how does a HRD use activate
an explosive squib breaks the flangible disc and releases
-
how do you check the level of extinguishing agent in a HRD
weighing the tank
-
true or false , Squibs are life limited
true
-
true or false , CO detector buttons are life limited
false
-
-
what is used as a propellant in a CO2 system
Nitrogen
-
why is orienting fixed CO2 bottles important
if not oriented correctly , the pickup may not be able get all CO2
-
What test must be done on all CO2 bottles every 5 years
Hydrostatic testing
-
Which loop detection circuit uses Ceramic beads?
Fenwall
-
How many electrodes are used in a fenwall continuous loop?
1 center conductor and inconel tubing is used for ground
-
In a fenwall loop circuit what are the glass beads covered with?
Eutectic salts
-
How many conductors are in a kidde loop system?
2 , one positive and one ground, also inconel tube is ground
-
what is the material surrounding the center conductor in a kidde loop system called?
Thermistor or thermal resistor material
-
of the pnuematic loop systems , which one is flexible and bent by hand?
Lindberg, Systron-Donner is rigid
-
When checking routing of loop systems in hinge-clamped lines what must be looked at?
that the insulators split is toward the outside of the bend
-
What is the proper distance of the clamps supporting a loop system?
8-10 inches
-
What does a jetcal analyzer do?
used to physically test a sensing element by applying a known heat to see when the alarm is activated
-
What is a example of class A fire zone?
Recip engine compartments
-
What is an example of a class D fire zone?
Wheel well or inside of wing (little or no airflow)
-
What are the 3 continous loop systems?
- Fenwal
- Systron-Donner
- Meggitt
-
What is the benefit of a meggitt loop system?
If the loop breaks and the gas escapes it gives a fault indication
-
On the lindberg loop system what is the pnuematic bellows assembly that senses pressure increase called?
Responder
-
In a loop system what is the metal called that absorbs and releases gas?
discreet material
-
Which spot system uses thermocouples?
Edison
-
What is the benefit of a double loop system?
if the positive side grounds out , it switchs polarity and still works
|
|