____ WILL COMPLETE THE ROLL CALL TO CONFIRM THE TOTAL NUMBER OF PERSONNEL UNACCOUNTED FOR
COMMAND
-
ON STRUCTURES OTHER THAN SMALL, SINGLE FAMILY RESIDENCE, ____ SHALL BE REQUESTED
AN ADDITIONAL ALARM
-
ANY COMPANY OFFICER WHO SUSPECTS OR IS NOTIFIED THAT THERE IS A MISSING OR TRAPPED FIREFIGHTER SHALL IMMEDIATELY NOTIFY ___
THE IC, OR SECTOR OFFICER IF ESTABLISHED
-
WHEN ARRIVING FOR DUTY ALL PERSONNEL SHALL:
- CHECK IN WITH THE COMPANY OFFICER
- REMOVE FROM THE PASSPORT THE NAMETAG OF THE PERSONNEL THEY ARE RELEIVING
- PLACE NAMETAG ON THE COMPANY PASSPORT
- REPLACE THE REMOVED NAMETAG BACK ON THE UNDERSIDE BRIM OF THE HELMET OF THE RELIEVED PERSONNEL
-
_______ CHARTS WILL ALSO BE KEPT IN THE COMMAND VAN
COMMAND POST ACCOUNTABILITY CHARTS AND LOBBY STATUS
-
IF PERSONNEL DO NOT RESPOND, RESPOND THAT THEY HAVE A MISSING FIREFIGHTER, OR IF A MAYDAY IS CALLED _____ ANNOUNCE: "ALL COMPANIES ON-SCENE, ___ IS UNACCOUNTED FOR. ANYONE KNOWING THE WHEREABOUTS OF ___ NOTIFY COMMAND IMMEDIATELY."
COMMAND WILL THEN IMMEDIATELY ASSIGN ______ TO PREPARE FOR SEARCH AND RESCUE.
- COMMAND SHALL
- A CHIEF OR SENIOR OFFICER AND THE RIT
-
SIGNAL 24
EQUIPMENT CARRIED SHALL DEPEND UPON
_____ THE SITUATION ENCOUTERED AND BE DETERMINED BY THE COMPANY OFFICER
-
DEPENDING UPON CONDITIONS, PUMP OR AERIAL OPERATORS ENGAGING IN OUTISDE OPERATIONS SHALL DON PPE WITH THE FOLLOWING BEING OPTIONAL:
-
WHEN STANDING-BY AT HYDRANTS, COMPANIES SHALL ENSURE AN ADEQUATE WATER SUPPLY BY REMOVING THE STEAMER CAP AND OPENING THE HYDRANT _____
PRIOR TO ATTACHING THE SUPPLY NOSE
-
TANKER ASSIGNMENTS
USE OF TANKERS WILL BE AT THE DISCRETION OF THE ASSIGNED SUPPRESSION DISTRICT CHIEF
-
ANYTIME A TANKER SHUTTLE IS IMPLEMENTED
RESERVOIR TANKS SHOULD BE CONSIDERED
-
RESPONDING COMPANIES NOT ON THE INITIAL RESPONSE SHALL MAKE RADIO CONTACT WITH
THE IC FOR INSTRUCTIONS BEFORE ARRIVING AT THE SCENE
-
___ INCREASES THE CHANCES OF SAVING LIVES AND PROPERTY
AN AGGRESSIVE, PROPERLY PERFORMED INTERIOR FIRE ATTACK
-
A CRITICAL COMMAND DECISION RELATES TO
THE OFFENSIVE/DEFENSIVE STRATEGIES OF THE SITUATION
-
OFFENSIVE STRATEGY SHOULD BE ABANDONED WHEN:
- THE EXTENT OF THE FIRE PROHIBITS EFFECTIVE SUPPRESSION
- OR
- THE STRUCTURE BECOMES UNSAFE
-
IT IS THE IC'S RESPONSIBILITY TO PROVIDE FOR LIFE SAFETY; AND TO CONTINUALLY DETERMINE IF
THE INVOLVED BUILDING IS TENABLE FOR INTERIOR OPERATIONS. TO PROTECT PERSONNEL WORKING ON-SCENE, A STRUCTURED METHOD OF EVACUATION MUST BE UTILIZED.
-
WATER SUPPLY SECTOR
- LOCATES AND EVALUATES WATER SOURCES
- ENSURES THAT PUMPERS ARE OPERATING AND BEING OPERATED PROPERLY
- ORGANIZES TANKER SHUTTLE EVOLUTIONS
-
AIR SUPPLY SECTOR
- ENSURES ADEQUATE AIR SUPPLY FOR WORKING PERSONNEL
- FILLS EMPTY AIR BOTTLES
- DISTRIBUTES FULL BOTTLES TO NECESSARY AREAS
- REQUESTS ADDITIONAL AIR UNITS AND COMPRESSORS IF NEEDED
|
|