What systems are operated by pneumatic air? 2-1
Air Conditioning, Pressurization, and Ice protection
_____ bleed air automatically supplements the _____ flow as necessary during periods of low engine rpm. 2-1
HP, LP
What compressor stage is the LP (P2.5) bleed air taken from? 2-2
5th
What compressor stage is the HP (P3) bleed air taken from? 2-2
6th
How is the HP valve controlled? 2-2
Electrically
How is the HP valve operated? 2-2
Pneumatically
If electric power to the HP bleed valve fails what position would the valve be in? 2-2
Closed
What are the reasons the HP valve would automatically close? 2-2
Bleed air line overheats (exceeds 288ºC)
Bleed air line has excessive pressure (exceeds 76 psi)
Fire handle is pulled
Engine is shutdown
Main DC bus power is lost
If electric power to the LP bleed valve fails what position would the valve be in? 2-2
Open
What are the reasons the LP bleed valve close automatically? 2-2
Bleed air line overheats (exceeds 288ºC)
Bleed air line has excessive pressure (exceeds 43psi) downstream of the valve
Fire handle is pulled
Air conditioning pack overheats (exceeds 225ºC)
Air conditioning duct overheats (exceeds 82ºC)
What does a BLD CLOSED light indicate? 2-2
The respective BLD valve is closed
What does a BLD FAULT light indicate? 2-2
The respective BLD valve received a closed signal but did not close
Bleed air line overheats (exceeds 288ºC)
Bleed air line has excessive pressure (exceeds 43psi) downstream of the valve
What does a HP HIGH light indicate? 2-2
The respective HP valve received a closed signal and did not close
How is HP bleed air cooled? 2-3
Through a ram air heat exchanger (precooler)
A separate flow through the precooler accomplishes _____ cooling for use by the pneumatic deicer system. 2-3
LP bleed air
How are the pneumatic systems interconnected so that one bleed air source can supply both air conditioning systems? 2-3
Cross Valve (X VALVE)
When can the cross valve be used? 2-3
On ground only
What is required for the X Valve to open? 2-3
One bleed valve must be closed
How is the X Valve operated? 2-3
Pneumatically
How is the X Valve controlled? 2-3
Electrically
What does a X VALVE OPEN light indicate? 2-3
X Valve is open
What does a BLD AIR LEAK light indicate? 2-3
Excessive temperature in the bleed line (exceeds 205ºC)
Will a BLD LEAK close the LP bleed valve? 2-3
No
What does a RECIRC light indicate? 2-12
A failure of the recirc fan (less than 80%)
Will you get a Master Caution light for a Recirc Fan failing? 2-12
No
What overhead light will not illuminate an AIR COND light on the CWP? 2-12
L/R RECIRC light
When is the Auto mode of the temp control to be used? 2-15
Always unless inop
Does the Manual mode of temp control provide temperature limiting protection to the system? 2-15
No, only Auto mode does
In the Manual mode of temp control, how long does it take to move the control valve from one extreme to the other extreme? 2-16
6-8 seconds
What does an AVIONICS VENT light on CWP indicate? 2-16
Failure of the avionics vent fan
While in flight, if the PRESS DUMP switch is activated what happens? 2-20
The primary outflow valve is immediately fully opened
While on the ground if the PRESS DUMP switch is activated what happens? 2-20
The primary and secondary valve are both fully opened
In Auto pressurization mode what is the max differential? 2-24
7.1psid
How long after touchdown is the primary outflow valve fully opened? 2-24
20 seconds
Where is the primary outflow valve located? 2-25
False bulkhead in the tail compartment
How are the outflow valves controlled? 2-25
Electric and Pneumatic
The outflow valves limit positive pressure to? 2-25
7.6psid
The outflow valves limit negative pressure to? 2-25
-0.5psid
If vacuum pressure is lost what position do the outflow valves revert to? 2-25
Closed
In manual pressurization mode what position is the primary outflow valve in? 2-25
Closed
What does a CABIN PRESS light indicate? 2-26
Cabin altitude above 10,000’ or cabin press exceeds 7.5psi
Where is the secondary outflow valve located on the Saab 340? 2-26
Rear pressure bulkhead
The secondary outflow valve is normally only operated in what mode? 2-26
Manual mode
What rate of cabin VSI does the detent on the auto controller provide? 2-27
500 fpm up and 300 fpm down
When would the fault light on the pressurization controller illuminate? 2-27
With a system failure
During a system self-test and extinguishes with no faults detected