Battery Start Right Engine Call Out
"This will be a battery start of the right engine. Ill time the start, you time from condition levers low idle to light off, and monitor fire guard. Check right side clear. Left Side is clear and fire guard is posted. Starting the right engine"
SIGNAL (hook em) START TO LINEMAN
-
Starter
- HACK THE CLOCK
- - IGN/START (check ignition light)
-
N1 -
-"Rotation" when N1 Moves
- Above 12%
- Battery Volts >18
-
-
-
ITT and N1 -
- Monitor (1,090C is Max ITT)
- - If no rise in ITT after 10 sec - Fuel Cutoff and Starter switch to off, wait 60 sec to drain fuel and monitor starter for min 15 sec
- - if ITT likely to exceed 925C, fuel cutoff and check battery, and report to Mx
-
Starter
Off when N1 is at 50% (P stop clock and check time)
-
Engine Instruments
- Check
- ITT max 685
- PROP RPM 900-1100
- Oil Px Min 40psi
- Oil Temp Neg 40 to 99
THUMBS UP TO LINEMAN
-
Power Lever
Advance to 70% N1
-
-
CONTROL CHECK / FLAPS CHECK
-
Rt. Generator
After load falls below 0.5 turn OFF
-
SECOND ENGINE CALL OUT
"This will be a generator assisted start of the left engine. The brief remains the same. Check right side clear. Left side is clear. Starting left engine"
1 finger up to lineman
-
Starter
HACK CLOCK
IGN/START (check IGN Light)
-
-
Generator (operative engine)
RESET, ON
-
Operative Engine ITT and N1
if ITT likely to exceed 790C, abort the start. Reattempt the start with Operating Engine N1 at 85%
-
Condition Lever
- Low Idle
- - hand on igntion lever until starter is off
CP hacks clock
-
Fuel Flow
Note. Approx 100 PPH
-
ITT and N1 Both Engines
- Monitor (1090C Max ITT)
- If no rise in ITT after 10 sec - Fuel Cutoff and Starter switch to off, wait 60 sec to drain fuel and monitor starter for min 15 sec- if ITT likely to exceed 925C, fuel cutoff and check battery, and report to Mx
-
Starter
- Off (min 50% N1)
- Hack clock and check time
-
Engine Instruments
- Check
- ITT Max 685
- Prop RPM 900-1100
- Oil Px Min 40
- Oil Temp -40 to 99
-
Generator (for first engine started)
OFF
-
Fuel Quantity indicators
- Check
- - if not working, may have busted current limiter
-
Generators
- On - one at a time
- check w/in .1
-
-
|
|