LOSS OF ALL GENERATORS
EMERGENCY PWR SWITCH -------ON
LOSS OF ALL ENGINES
EMERGENCY PWR SWITCH -------- ON
STARTER VALVE FAILS TO CLOSE
ENGINE START BUTTON-------VERIFY OUT
ABNORMAL START
FUEL LEVER------------OFF/DETENT
ENGINE START BUTTON---------IN/LT ON /MOTOR
FOR 30 SECONDS
PNEUMATIC MANIFOLD FAILURE
ASSOCIATED ENG PNEUMATIC SUPPLY SELECTORS--- OFF
PNEUMATIC TEMP HI LIGHT ON AND/OR INDICATOR OVER LIMIT MARK
ENGINE PNEUMATIC SUPPLY SELECTOR --- OFF
GALLEY FIRE AND/OR GALLEY OVERHEAT LIGHT ON
GALLEY BUS SWITCHES NO 1,2 AND 3 OFF
SLAT DISAGREE LIGHT ON AFTER COMMITTED TO T/O
INCREASE SPEED TO AND MAINTAIN NO LESS THAN V2 + 10. DO NOT RETRACT THE FLAPS
RUNAWAY STAB TRIM
SELECT OPPOSING TRIM WITH LONGITUDINAL TRIM HANDLES
GROUND PROX WARNINGS
THRUST---- EMERGENCY
PITCH------ ROTATE TOWARD 15 DEGREES
FLIGHT PATH---CONTROL WITH PITCH AS NECESSARY
ATC--- ADVISE
"DON'T SINK"
THRUST AND PITCH ATTITUDE-----ADJUST TO SILENCE ALERT
"SINK RATE" OR "GLIDESLOPE"
AT OR ABOVE 1000 FEET- IMC OR 500 VMC
: THRUST AND PITCH ATTITUDE-----ADJUST TO SILENCE ALERT
BELOW 1000 FEET- IMC OR 500-VMC
MISSED APPROACH -------EXECUTE
"TOO LOW, GEAR or TOO LOW FLAP
"
MISSED APPROACH-------EXECUTE
"BANK ANGLE"-
--- BANK AND ROLL RATE DECREASE.
CABIN ALT WARNING OR RAPID DECOMPRESS/EMER DECENT
OXYGEN MASKS AND REGUALTORS--------ON 100%
COMMUNICATIONS-----ESTABLISH
EVACUATION
EMER POWER------ON