Exam 3 Realz.txt

  1. The Red Indicator on the back of the Endo Clip 5mm indicates that the instrument ___?
    is out of clips
  2. Following trocar entry into the Abdominal Cavity (during lap procedure), the ___ is removed and the ____ remains in its place.
    Obturator, Cannula
  3. The Endo GIA universal places two ___ staggered rows of ___ staples?
    Triple, Titanium
  4. The Versaport Plus V2 trocar system is available in the following cannula diameters?
    5mm, 11mm, 12mm
  5. What is Ethicon�s offering to compete with our GIA?
    TLC
  6. The Purstring 45 has ___ suture and the Purstring 65 has ___ suture?
    2-0 Surgidac , 2-0 Monosof
  7. The Echelon 60 can be reloaded ____ times for a total of ____ firings?
    12 of 12
  8. The ____ safety band on the Surgineedle indicates the position of the blunt stylet?
    Red
  9. The Visiport Plus trocar is available in the following diameters?
    5-11mm, 5-12mm
  10. The membranous lining of the abdominal cavity beneath the posterior fascia is called?
    Peritoneum
  11. What Ethicon offering competes directly with our TA 45 stapler?
    Contour
  12. The 3 parts of the small intestine are?
    Duodenum, Jejunum, Ileum
  13. The uterine arteries are contained bilaterally within the _____ ligaments.
    Cardinal
  14. Define Ipsilateral
    On the same side of
  15. What is the shaft length of the Endo Clip III device?
    33cm
  16. During the Lap Chole, the Endo GIA universal is commonly used to transect the cystic artery and cystic duct.
    False
  17. The adnexa of the uterus includes the following structures?
    Broad Ligament, Round Ligament, Ovarian Ligament, Fallopian Tube
  18. What structure are ligated and divided during a Lap Chole?
    Cystic duct and cystic artery
  19. What hand pieces are available with the Autosonix system?
    Ultra Shears, Hook Probe, Ball Probe
  20. The Echelon 60 is available in what staple leg lengths?
    2.5, 3.5, 3.8, 4.1
  21. What is the surgical terminology for the joining of the stomach to the 2nd part of the small intestine?
    Gastrojejunostomy
  22. The trigger mechanism on the Visiport Plus optical trocar system requires a manual retraction of the knife blade after firing?
    False
  23. When the 15mm VersaStep access system is used as a secondary port, the needle/sleeve assembly can be inserted in one step?
    True
  24. The Endo GIA Universal can articulate ____ and ____ degrees?
    22 & 45
  25. Select the benefits of radial dilation seen with the Versastep Access System?
    Lower incidence of post-op port site hernia, decreased port site pain resulting from tissue dilation rather than cutting, increased safety based on blunt dilation
  26. The DST series TA 90 stapler is available in 2.5mm, 3.5mm, 4.8mm loads?
    False
  27. What vessels do you need to ligate and divide in order to perform a Lap Nissen Fundoplication?
    Short Gastrics
  28. The Endo GIA Universal can be loaded with cartridges that are ___ mm, ___ mm, and ___ mm leg lengths?
    30, 45, 60
  29. During Laparoscopy, the Hasson Technique refer to:
    Open laparoscopy (without the use of Veress Needle)
  30. The Endo Clip II applier has ___ clips and the Endo Clip III applier has ___ clips.
    20, 18
  31. The DST series GIA 100 is available in 2.5mm, 3.5mm, and 4.8mm reloads?
    False
  32. The VersaStep Plus access system comes in the following cannula lengths:
    70mm, 110mm, 150mm
  33. The ETS Flex 60 is available with what staple leg lengths?
    2.5mm, 3.5mm, 4.1mm
  34. The closed length is ___ mm for the Endo Clip III and ___ mm for the Ligamax 5.
    9.1, 8.8
  35. The AutoSonix system consists of a generator box, transformer, and hand instruments?
    False - transducer
  36. At the start of a Lap case, the surgeon uses the Surgineedle to create?
    Pneumoperitoneum
  37. The Ethicon CDH/Stealth come in the following sizes:
    21, 25, 29, 33
  38. Which of the following instruments can be used to ligate the cystic duct and cystic artery during a Lap Chole?
    Endo Clip II & Endo Clip III
  39. The landmark separating the Duodenum from the Jejunum is called____?
    The Ligament of Treitz
  40. Ethicon�s Contour stapler can be reloaded __ times for ___ firings?
    5 for 6
  41. The complete separation of wound edges post op with protrusion of abdominal organs is called______?
    Evisceration
  42. Surgeon controlled clip closure with the Endo Clip II indicates that the surgeon___
    May vary the degree in closure by controlling the closure of the clip
  43. Because of the high frequency vibrations produced by the AutoSonix system, electrical energy transfer to the target tissue is _____.
    Eliminated
  44. The term pneumoperitoneum can be defined as:
    Pressurized gas in the abdomen during a Lap procedure
  45. The Blunt Tip Trocars have built in converters to accommodate what size instruments?
    5mm, 7mm, 8mm
  46. The VisiPort Plus access system can be used with or without insufflation based on the surgeons discretion?
    True
  47. The Mediastinum is the space that divides the plural cavity and it contains:
    Heart, Pericardium, Esophagus, Major Vessels, Trachea, Nerves
  48. What size trocar (minimum diameter) is required for insertion of theEndo Clip II?
    10mm
  49. Closing fascia is commonly considered necessary with cutting trocars that are ____ or larger in diameter?
    10mm
  50. A Lap Chole offers a number of advantages over the open approach.
    Hospital stay shortened, Recovery time shortened, smaller incisions
  51. With the VersaPort V2 5-11mm trocar, the VersaSeal Plus allows the surgeon to use hand instruments up to 12mm without using an additional converter?
    False
  52. Define Cephalad
    Toward the Head
  53. The VersaStep Plus 12mm access system is a ____ part system consisting of a ____
    4 part, needle, cannula/dilator, radial expandable sleeve, versaseal plus
  54. The features of ultrasonic dissection and coagulation with the AutoSonix system are:
    Reduction of thermal spread, reduction of tissue charring, no risk of grounding injuries
  55. What is the name of the only competitive Single Incision Port on the market?
    Olympus Triport
  56. What incision is used for an appendectomy?
    McBurney
  57. Narrowing of a tube, duct, or hollow organ is called a:
    Stricture
  58. The term �ligate� means to:
    Tie off, or occlude
  59. Closing fascia is commonly considered necessary for cutting trocars that are _____ or larger in diameter?
    10mm
  60. Who is viewed as the leader of the VAC?
    Supply Chain Executive
  61. Who has the most influence on the VAC?
    The Surgeons
  62. The Premium Multifire Skin Stapler can be reloaded ____ times?
    2
  63. What is a TAHBSO?
    Total Abdominal Hysterectomy w/a Bilateral Salpingo Oophorectomy
  64. Which DST series EEA stapler diameters are available with 3.5 mm staples?
    21, 25, 28
  65. The weight loss procedure that is most often performed is the:
    Roux en Y
  66. What is the core objective of the VAC?
    To remove subjectivity
  67. The ETS is available in what staple lengths?
    2.5mm, 3.5mm, 4.1mm
  68. What is Ethicon�s offering that directly competes with our TA 45 Stapler?
    Contour
  69. The DST Series EEA has _______ than the PPCEEA
    Larger Lumens
  70. Define Ascites:
    The Accumulation of fluid within the abdominal cavity
  71. The ETS Flex can be reloaded ____ times for a total of ____ firings.
    7, 8
  72. Which instruments are used to ligate the cystic duct and cystic artery during a Lap Chole?
    EndoClip II or EndoClip III
  73. What size incision is recommended when using a SILS port?
    20mm
Author