Vent settings.txt

  1. Volume targeted ventilation initial frequency
    8-12 breaths/min
  2. Volume targeted ventilation initial VT tidal volume
    4-12 ml/kg IBW

    6-10 most often used
  3. Volume targeted ventilation initial Ve (minute ventilation)
    5-10 lpm

    Check that f and Vt give sufficient Ve
  4. Volume targeted ventilation initial Vi (inspiratory volume)
    • 40-100 lpm
    • 40-60 most commom
  5. Volume targeted ventilation initial TI (inspiratory time)
    0.8 - 1.2 sec
  6. Volume targeted ventilation initial waveform
    • Square
    • Decel ramp
    • Sine
  7. Pressure targeted ventilation initial f
    8-12 bpm
  8. Pressure targeted ventilation initial PIP
    ~15 cmH2O
  9. Pressure targeted ventilation initial TI (inspiratory time)
    0.8-1.2 sec
  10. Mechanical ventilation initial PEEP
    5-10 cmH2O
  11. Mechanical ventilation initial sensitivity
    -0.5 - -2 cmH2O from baseline
  12. Mechanical ventilation initial FiO2
    0.21 - 1.0 to get PaO2 of 60-100 mmHg