  1. In section 2.10.3.3(A), receptacles shall be installed such that no point measured horizontally along the floor line of any wall space is more than __________ from a receptacle outlet.
    1800 mm
  2. As used in Section 2.10.3.3(A)(2)(1), a wall space shall include any space _____ or more in width (including space measured around corners) and unbroken along the floor line by doorways and similar openings, fireplaces, and fixed cabinets that do not have countertops or similar work surfaces.
    600 mm
  3. A receptacle outlet shall be installed at each wall countertop and work surface that is _____ or wider.
    300 mm
  4. Receptacle outlets shall be located on or above, but not more than _____ above the countertop or work surfaces.
    500 mm
  5. At least one receptacle outlet shall be installed in bathroom within _____ of the outside edge of each basin.
    900 mm
  6. At least one receptacle outlet shall be installed in each vehicle bay and not more than _____ above the floor.
    1700 mm
  7. In dwelling units, hallways of _____ or more in length shall have at least one receptacle outlet.
    3000 mm
  8. Floor receptacles located more than _____ from the wall (or room divider) may not be counted as required receptacles.
    450 mm