CE700 Temperature Limits

  1. Min Battery Temperature for APU or Battery Start
    -20°C
  2. If BATTERY O'TEMP L/R EICAS displays on ground:
    Takeoff is prohibited, regardless if message clears
  3. Min ambient temperature for APU ground start:
    -40°C
  4. What must be selected ON while on the ground in icing conditions?
    ENGINE ICE PROTECTION, except during deicing/anti-aicing
  5. When operating in visible moisture and ≤ 10°C before takeoff, or if expecting icing ≤  400' AGL, select the following:
    L & R ENGINE - ON

    WING - ON

    STAB - ON
  6. Except for preflight check, max temperature for operation of WING ICE PROTECTION:
    15°C (use SAT for ground RAT for flight)
  7. Max temperature for operation of STAB ICE PROTECTION is...
    Time limit for operation above max temp...
    25°C (SAT)

    2 min
  8. Flight in freezing rain is...
    Prohibited
  9. Limit ground operation of PITOT/STATIC ON to..
    2 min
  10. If in ground icing conditions, at 1 min prior to takeoff, select:
    PITOT/STATIC ON for 15 sec then NORM
  11. Adhere to Engine Operating Cold Temperature table (AOM 12.15.2) when:
    On the ground @ idle

    Visible Moisture ≤ 1 mile

    Temp < 0° & temp/dew point =
  12. Begin using conditioned air and close doors when…
    Temp > 35°C after 60 min

    ≥ 45°C; 30 min
  13. Min oil temperature for motor or start
    -40°C
  14. Min oil temperature for power above idle
    10°C
  15. Min oil temperature for acceleration to climb thrust or higher
    15°C
Author
ddubon
ID
361183
Card Set
CE700 Temperature Limits
Description
REV 1.0.0 30JAN23
Updated