What is the term for conductors that originate at the terminals of a circuit breaker or a circuit recloser in a distribution substation and continue to the termination point of the high side of distribution transformers?
D) Distribution feeder circuits
A study of 10 linemen who regularly worked on energized 345 KV transmission lines
conducted by personnel at John Hopkins University for a 10 year period concluded
what about the health of the linemen?
A) The linemen were in excellent health
Why are direct current transmission systems used?
B) To interconnect two AC systems which are not synchronized
Given a primary metering installation on a 13,200 / 7,620 volt system with the primary WYE connected to the voltage transformer and a secondary voltage of 120 volts, what is the turn’s ratio of this voltage transformer?
D) 63.5/1
What does the term LSC stand for?
B) Light sensitive control
What is the term to describe a luminous discharge created by the ionization of air surrounding an electrical conductor?
D) Corona
What would cause an ATO to switch from the preferred feed to the alternate feed?
B) A power interruption on the preferred feed for a preset amount of time
Why is the capacity of an underground transmission system severely limited when cables are installed in ducts?
D) The duct limits the cables ability to dissipate heat generated in the cable
High-pressure, oil-filled, paper-insulated cables in which three phase conductors are enclosed in a steel pipe containing oil are used for underground transmission circuits.
True
Phase sequence has no effect on poly-phase motors.
False
How is an electronic sectionalizer reset?
B) Install a new actuator and close the gate with a hotline tool
An auto booster with a 10/1 ratio (boosting) is on a line where the source voltage measures 6,927 volts.
The sliding contact is on tap 5 of the secondary coil. What is the corrected voltage on the load side of the auto booster?
B) 7,620
What should be done before replacing a three-phase transformer?
B) Rotation should be checked, marked and returned the same way
What is the bank KVA rating of two 50-KVA transformers that are connected in an open delta configuration?
B) 86.6 KVA
What does a yellow dot on the outside of a secondary pedestal indicate?
D) The pedestal feeds a streetlight
A 25 KVA transformer has a ratio of 27.5 to 1. If the primary voltage is 13,200, what is the rating of the secondary in KVA?
D) 25
If given a metering installation involving current transformers, what must be done prior to working on the secondary side of a current transformer for safety?
C) The CT must be shunted or bridged to prevent primary potential on the secondary side
If a customer needs 240 volt three-phase service, what secondary rating on the nameplate can be used?
C) 240 / 480
How many times will our field reclosers operate before they lockout?
D) Three operations and then lockout
There are three different types of substations. What are they?
B) Transmission, sub-transmission, and distribution
What type transformer is used in a series street lighting circuit?
C) Constant current
What device uses air, oil, SF6, gas or vacuum to break the arc when switching electrical circuits and equipment in and out of the system?
C) Circuit breakers
There are four basic types of switched capacitor banks. Which of the following are
switched capacitor banks?
A) Voltage, current, VAR, and Temperature
What is the safest way of completing electrical distribution work?
D) De-energize, isolate, test, and ground
When taking a regulator off line, after confirming the regulator is in the neutral position, what should be done before closing the bypass switches?
D) The selector switch should be turned to the off position
What is a clearance tag to be considered the same as?
A) A lock
ATO’s are installed to meet what customer requirements?
D) Customers with essential loads who require two electric sources with automatic transfer from one source to the other
What equipment reduces primary voltage to the utilization voltage required by the customer?
B) A distribution transformer
If the regulatory tap setting on a single-phase transformer is changed from tap C
(100%) to tap D (97.5), what happens to secondary voltage?
C) It will increase
What does the number 25 on a luminaire indicate?
A) 250 watts
Converter stations are used to convert AC transmission voltages to DC, and
vise-versa.
True
When paralleling transformers, what is the maximum allowable difference in rated impedance between the transformers?
D) Within 7.5% above or below each other
On a WYE / WYE bank, the primary neutral is floated to prevent excess voltage from building up on the secondary side.
False
Auto Boosters automatically adjust to changing loads and voltages.
True
What should be used to energize and de-energize oil filled equipment?
D) Appropriate insulated sticks
Why should rubber gloves be stored in canvas bags when not in use?
B) To protect them from mechanical damage or deterioration from ozone
A sectionalizer is found tripped. You patrolled the lines find nothing wrong and call dispatch for permission to close it back in. How do you close the sectionalizer back in?
C) Push up on the yellow ring with a hot line tool
What does protective equipment provide the lineman?
A) A margin of safety for error without injury
What are the two types of capacitor banks?
D) Fixed and switched
What is the purpose of current transformers used in substations?
D) To measure high current by reducing it proportionally to a manageable level
Given a 101 KVA or larger single phase overhead transformer, how many secondary bushings would you generally expect it to have?
D) Four
What is the most likely cause for a streetlight burning during daylight hours?
D) The photocell has failed
The need for a neutral is minor when the load is balanced among the three phases. For this reason, the neutral is often omitted in distribution and
transmission wye circuits.
True
Once secondary phase conductors have been removed from an energized
overhead transformer, they should be considered energized until the connection
status of both ends of the secondary mains are verified open and not paralleled
to another transformer.
True
What are the two main reasons linemen wear safety hard hats?
B) To protect the head from the impact of falling or moving objects and electrical contact
What is the phase to ground voltage in a 4160 four wire system?
D) 2400 volts
Which of the following is true of a transformer nameplate listing one secondary voltage of 277 volts?
D) The transformer has only one secondary coil
In addition to ensuring percent impedance of one transformer is between 92.5% and 107.5% of the other transformer, which of the following conditions must be met in order to parallel two single-phase transformers for greater capacity?
D) Only B and C
Which situation will cause a substation breaker to operate automatically?
D) All the above
Given a transformer that has a high side winding made with small wire and a large
number of turns and a low side winding that is made with larger wire and a fewer
number of turns, what type of transformer is this?
D) Step down transformer
What is the best rubber cover up component to use to cover up odd shaped conductors and equipment?
A) A rubber-insulating blanket
What test should be performed on rubber gloves before work each day?
B) Air test
Conductor covers, insulator covers, and cross arm covers are fabricated from rubber
and what other material?
A) High dielectric polyethylene
A sectionalizer is normally set to lockout at ________ count(s) less than the recloser lockout.
D) 1
Class 0 rubber gloves are AC proof tested to __________ volts rms and DC proof
tested to __________ volts average.
C) 5,000 and 20,000
Fuses are installed to protect the electrical system from what?
B) Faults and short circuits
What is the purpose of a lightning arrester in a distribution circuit?
B) To bypass electrical surges on the circuits, protecting the insulators and equipment from over voltages
An Auto booster is capable of lowering the voltage on a distribution line.
True
What is the most common type of lamp used by this company?
C) High pressure sodium
What is the voltage required by the primary winding in a transformer that has
2,400/4,160Y 120/240 on its nameplate?
C) 2400 volts
Primary metering is a cost saving installation that benefits the company and customers that use large amounts of power.
True
Which of the following is true regarding a three phase delta circuit?
D) All the above
Reactive kilovolt-amperes can be supplied to the electrical system by connecting___________ to the distribution circuits in the substations or out on the distribution lines to neutralize the effect of customer inductive loads.
B) banks of capacitors
How is an insulator hood properly installed?
C) It will overlap the line hose when properly installed
To keep from damaging underground cable when pulling it in, you must not pull beyond its maximum allowable tension or bend it greater than its allowable radius.
True
What device is used to check for a bad cell in a de-energized capacitor rack?
A) C-meter or microfarads meter
Auto boosters can only boost or only buck depending on how they are wired.
True
What do voltage or potential devices connected to coupling capacitors normally provide
power to?
D) Protective relays
Which of the following are methods of controlling light emissions from streetlights?
D) Reflectors, refractors and diffusing globes or a combination are used to direct and control light
How should rubber-insulating sleeves be treated by the lineman?
A) Rubber sleeves must be treated with care and inspected regularly by the lineman
What is the preferred method for de-energizing a switched capacitor bank?
C) Open switch in the control box with class two rubber gloves
What is the term for a transformer that contains protective devices such as lightning arrestors, primary fuses and secondary breakers?
C) CSP transformer
How is voltage regulation on any electrical system defined?
B) The difference in voltage between periods of no load and periods of full load on the system
What is calculated when the resistance, inductive reactance, and capacitive reactance are considered to determine the total opposition to current in a circuit?
C) Impedance
How are rubber goods easily damaged?
A) Only Improper storage and Exposure to grease and oil
After washing rubber gloves, what is the best thing to do next?
C) Rinsed thoroughly and left to air dry
When using a voltmeter to perform phasing on two known energized secondary circuits, what does a “0.00” reading indicate?
C) The two circuits being tested are the same phase
What is used to cover primary distribution conductors to protect the lineman from an accidental electrical contact?
A) Rubber insulating line hose
What is the maximum use voltage for class 2 rubber gloves?
D) 17, 000 volts ac rms
What is the most important article of protection for a lineman or cableman?
A) A good pair of rubber gloves with proper dielectric strength
Which of the following is true concerning a transformer with the following voltage rating on the nameplate:12,470GRDY/7,200?
C) Indicates the transformer has reduced insulation at the neutral end of the primary coil
What is the function of a protective relay in a substation?
A) Automatically operate their contacts to properly identify the source of the trouble and remove it from the electrical system
What procedure must be completed before connecting two energized secondary wires
together?
A) Use a voltmeter to ensure the phasing is correct
Each work project and especially those projects requiring linemen and cablemen to handle energized electrical conductors should be planned in detail. What should this plan ensure?
C) The safety of the workers and the reliability of the electrical service
What is the purpose of capacitor banks installed on distribution circuits?
B) To improve the power factor
There are two types of distribution regulators now in service. They are the induction and the step voltage regulators.
True
What causes a voltage drop in an electric circuit that causes voltage to be less at the load end than it is at the source end of a line?
C) Current flowing through the line impedance causes a voltage drop
What type of transformer connection is shown by the illustration?
C) Delta - Wye
Current and potential transformers supply the intelligence for measuring power flows and the electrical inputs for the operation of protective relays associated
with the transmission and distribution circuits.
True
The voltage variation to residences (secondary) has been standardized. What are the low and high limits?
C) 114 and 126
How many steps does an auto booster have, not counting the neutral position?
C) 5 steps wired for either boost or buck but not both
What component is used to regulate voltage on a line when capacitors are no longer
effective?
D) All the above
What should be done with metal structures and fences that are constructed under extra high voltage transmission lines?
B) Metal portions should be effectively grounded to bleed off static charges
What does the acronym “SCADA” stand for on an automated distribution system?
D) Supervisory Control and Data Acquisition
What limits the capacity of overhead AC transmission lines?
A) Thermal expansion and resulting sag of line conductors
What happens to the current on the neutral of a wye system when the loads between
the phases are not balanced?
A) The current goes up on the neutral
A sectionalizer senses fault current at what percentage of its operating current rating?
D) 160%
What is the term for a direct current transmission line consisting of one conductor with the ground as a return?
A) Monopolar DC system
What is the purpose of a sectionalizer?
C) Isolates faults and protects the feeder and distributor
On a delta circuit, there is no return current through the ground.
True