RTE2457 ImagingII

  1. _____ - Misrepresentation of the size of an object being examined
    Distortion
  2. The 2 types of distortion are?
    ____ - enlargement of an object on an image
    ____ - misrepresentation of the shape of an object on an image
    • Size distortion (magnification)
    • Shape distortion
  3. The 2 controlling factors that affect size distortion are?
    SID, OID
  4. SID

    Due to the divergent property of x-ray photons, only ____ as a type of size distortion is possible. (_____ not possible!)
    • Magnification
    • minification
  5. The relationship between SID & magnification is ______.
    Inverse
  6. Image Upload 2
  7. OID

    Due to the divergent property of x-ray photons, only _____ as a type of size distortion is possible. (Minimization not possible)
    Magnification
  8. The relationship between OID & magnification is _____.
    Direct
  9. Image Upload 4
  10. Image Upload 6
  11. Although both SID & OID control magnification, ____ has a greater effect on size distortion.
    OID
  12. Part Thickness & Magnification

    A thicker body part will _____ the OID
    Increase
  13. Best means of minimizing size distortion: use a far ___ & close ___!
    SID, OID
  14. SOD - Source to Object Distance
    The distance from source of radiation to object.
    SOD + ___ = ___
    SOD + OID = SID
  15. Calculating Size Distortion 
    M = SID/SOD
  16. Types of Shape Distortion
    ____ - object appears longer than its true size
    ____ - object appears shorter than its true size
    • Elongation
    • Foreshortening
  17. Factors that Affect Shape Distortion

    Controlling factors
    ____ - CR, part, IR
    ____ - direction & degree
    • Alignment
    • Angulation
  18. CR Alignment
    ___ - the theoretical center of the x-ray beam where photons exit the focal spot

    —- Because an x-ray beam diverges, only the ___ is truly perpendicular

    —- The further away the anatomy is from the CR, the greater the __________.
    • CR
    • CR
    • shape distortion
  19. Image Upload 8
  20. Anatomical Part Alignment

    Any body part not perpendicular to the CR or not parallel to the IR will have a greater degree of ______
    Shape distortion
  21. As CR, Part, and/or IR alignment increases, shape distortion ____

    As CR, Part, and/or IR alignment decreases, shape distortion ____
    • Decreases
    • Increases
  22. Angulation (Degree)

    As beam angulation increases, shape distortion _____
    As beam angulation decreases, shape distortion
    _____
    • Increases
    • Decreases
  23. Image Upload 10
  24. Image Upload 12
    Image Upload 14
Author
Marc817
ID
349320
Card Set
RTE2457 ImagingII
Description
Unit 7 - Distortion