Electrical Safety Rating Exam Flash Cards 2019

  1. What amount of current is potentially fatal if it passes through a person’s body for 1 second or more?




    A) 1.0 milliampere (mA)
  2. Final approval to work on an energized switchboard is required from which of the following persons?




    B) The Commanding Officer
  3. Which of the following characteristics of electrical-grade rubber gloves is the basis for their classification?




    B) Rubber wall thickness of the glove
  4. What program is designed to provide for personnel and ship safety and prevent damage to equipment while
    conducting routine preventative maintenance or repair actions?




    A) Tag-out program
  5. What item is used as a precautionary measure and provides temporary special instructions for the operation
    of equipment?

    A) Caution tag
    B) Danger tag
    C) Out-of-commission tag
    D) Out-of-calibration tag
  6. What term describes areas that are typically wet, oily, or electrical spaces?




    B) Hazardous Spaces
  7. What electrical resistance level is the human body typically categorized in?




    A) Low
  8. When skin is damp, how low can body resistance be measured?




    B) 300 ohms
  9. What person is overall responsible for the 3M aboard the ship?




    D) Commanding Officer
  10. What NSTM covers basic electrical safety and guidelines for handling energized equipment?




    A) NSTM 300
  11. What is the minimum number personnel that have to be CPR qualified before conducting an IVV?




    C) 1
  12. You should always assume electrical equipment is de-energized.


    A) False
    B) True
    A) False
  13. When two or more repair groups are performing repairs on a system, the responsibility for posting a danger
    tag rests with whom?




    A) Each repair group
  14. If a person is unconscious because of an electric shock, you should start artificial respiration at what point?




    C) As soon as possible
  15. A person has stopped breathing but is still alive. This person is said to be in which of the following states?




    C) Respiratory failure
  16. What equipment is needed for conducting an initial voltage verification?




    B) rubber mat, electrical rubber gloves, face shield
  17. What fire-extinguishing agent is the safest type for use on an electrical fire?




    A. Carbon dioxide (CO²)
  18. During a fire, what person determines whether the power should be secured?




    A) The repair party electrician
  19. When it is necessary to rig casualty power cables, what person(s) is/are responsible for tying the cables up in
    the overhead?




    C) All members of the repair party
  20. Rubber gloves are required for initial voltage verification at all times.

    A) True
    B) False
    A) True