-
What does the amber color represent?
LED in transit
-
What does the green color represent?
LED in extend or full extend position
-
What is wrong if the if all lights are extinguished?
Nothing
-
Why do the leading edge flaps have only two positions on the annunciator?
There are only two positions: retracted or extended
-
Why do the leading edge flaps have three positions on the annunciator?
There are three positions: retracted, extended or full extended
-
When might a green light be an indication of an abnormal condition?
LED jammed or in an improper/uncommanded position
-
If the annunciator panel was inoperative, where could you monitor the LEDs in transit?
Forward instrument panel LE FLAPS IN TRANSIT light
-
Is autoslat movement displayed on the LED annunciator panel?
Yes
-
Is autoslat movement displayed on the LE FLAPS IN TRANSIT light on the center forward panel?
No, this light is inhibited during autoslat operations
-
Do the LED annunciator lights test with the MASTER lights test switch on the forward panel?
Yes
-
At what flap settings do the slats move to the EXTEND position?
1,2,5
-
At what flap setting do the leading edge flaps move to FULL EXTEND?
Flaps 1 or greater
-
At what flap settings do the slats move to the FULL EXTEND position?
Flaps 10 or greater
-
Why are the flap handle gates positioned at the 1 and 15 degree settings?
Those are the go-around flap settings
-
How are the trailing edge flaps normally operated?
Hydraulically from System B
-
How can the trailing edge flaps be extended if Hydraulic system B fails?
Electrically through the alternate flaps position switch
-
What happens when the ALTERNATE FLAPS switch is moved from OFF to ARM?
Standby hydraulic pump activates
Alternate flap position switch activates
Trailing edge flap bypass valve closes
-
Can the trailing edge flaps be retracted with the ALTERNATE FLAPS position switch?
Yes
-
What features are not available during alternate flap operation?
Asymmetry and skew protection
-
What happens to the leading edge devices when the ALTERNATE FLAPS position switch is actuated?
All leading edge devices go to full extend
-
Can leading edge devices be retracted if the ALTERNATE FLAPS position switch is actuated?
No
-
Does the ALTERNATE FLAPS position switch have to be held until the leading edge devices arrive at the desired position?
No, it is a momentary switch. All LEDs go to full extend.
-
Does the ALTERNATE FLAPS position switch have to be held until the trailing edge flaps arrive at the desired position?
Yes
-
Does the ALTERNATE FLAPS position switch have to be held in order to retract the flaps?
No, it is held magnetically
-
What is the ALTERNATE FLAPS duty cycle for flaps 1 to 15?
5 minutes OFF
-
What is the ALTERNATE FLAPS duty cycle for flaps greater than 15?
25 minutes OFF
-
What can be determined by the trailing edge flap position indicator?
Flap position, asymmetry or skew
-
What electrical power is required for the trailing edge flap position indicator to function?
AC power (transfer bus #2)
-
How would you be able to determine that an asymmetric flaps situation exists?
Split indicator needles
-
What does #12 indicate?
Illuminated (amber) –
-indicates failure of the auto slat system
-indicates failure of a single Stall Management/Yaw Damper (SMYD) computer when illuminated during MASTER CAUTION recall and extinguishes when master caution system is reset.
|
|