1. Large hand line nozzle sizes
    2 1/2" solid stream nozzle with 1-1/8" tip and 2 1/2" fog nozzle
  2. GPM and FL for solid stream nozzle 1-1/8" tip, 3" line
    266 GPM / 6 psi
  3. GPM and FL for 2-1/2" fog nozzle, 3" line
    250 GPM / 5 psi
  4. GPM for SM-20
    150 GPM
  5. GPM for SM-30
    200 GPM
  6. FL per 100 ft of 1-3/4" hose with SM-20
    24 psi
  7. FL per 100 ft of 1-3/4" with SM-30
    38 psi
  8. FL for wye
    10 psi
  9. Recommend pressure for 250 ft of preconnected 1-3/4" with SM-20
    161 psi
  10. Recommend pressure for 200 ft of preconnected 1-3/4" with SM-30
    175 psi
  11. FL per 100 ft of 3" hose flowing 150 GPM
    2 psi
  12. FL per 100 ft of 3" hose flowing 200 GPM
    3 psi
  13. FL per 100 ft of 3" hose flowing 300 GPM
    7 psi
  14. FL per 100 ft of 3" hose flowing 350 GPM
    10 psi
  15. FL per 100 ft of 3" hose flowing 400 GPM
    13 psi
  16. Manufacturer of fog nozzles
    Elkhart Brass Co.
  17. Manufacturer of 1" nozzles
    Akron Brass Co.
  18. NP for 1" fog nozzle
    100 psi
  19. GPM for 1" fog nozzles (booster hose)
    13 - 60 GPM
  20. NP for solid stream tips on master stream
    80 psi
  21. NP for fog nozzle on master stream
    100 psi
  22. FL for portable monitor set or deck gun
    25 psi
  23. NP for cellar nozzle
    100 psi
  24. GPM for cellar nozzle
    260 GPM
  25. FL for cellar nozzle pipe
    10 psi
  26. Diameter of water distribution for cellar nozzle
    55 ft
  27. FL for stand pipe system
    25 psi
  28. FL for each additional floor for a standpipe system
    5 psi
  29. Psi of Sprinkler System
    Always 150 psi
  30. Recommended NP for fog nozzle
    100 psi
  31. Recommended NP for 3" handline solid stream nozzle
    50 psi
  32. Recommended pressure for Quints
    200 psi
  33. NP for quint solid stream nozzle
    80 psi
  34. NP for quint fog stream nozzle
    100 psi
  35. NP for solid nozzle for deck gun or portable monitor
    80 psi
  36. NP for fog nozzle on deck gun or portable monitor
    100 psi
  37. Recommended pressure for foam eductors
    200 psi
  38. Discharge pressure for source truck and relay trucks for relay pumping
    175 psi
  39. FL for a reducer
    10 psi
  40. GPM for 1-1/2" tip on a monitor
    598
  41. GPM for 1-3/4" tip on a monitor
    814
  42. GPM for 2" tip on a monitor
    1063
  43. Foam eductor on Ladder 12 and GPM
    Akron 3095 - 95 GPM
  44. FL per 100' of 3" for the cellar nozzle
    5 psi
  45. Maximum hose length for Foam Eductor
    250'
  46. 0-10% drop
    3 x first line
  47. 11-15% drop
    2 x first line
  48. 16-25% drop
    1 x first line
  49. Equation to find % drop
    [(Static pressure - Residual pressure) x 100] รท Static pressure
  50. GPM for 1000' of 3" discharge line for relay pumping
    440 GPM
  51. Reasons not to adjust to 175 psi during relay pumping
    Intake drops below 20 psi, throttling up does not increase discharge pressure, or throttling up does not increase engine rpm
  52. FL per 100' of 3" line flowing 100 GPM
    1 psi
  53. FL per 100 ft of booster line
    8 psi
  54. Elevation compensation
    +/- 5 psi for every 10% change