Large hand line nozzle sizes
2 1/2" solid stream nozzle with 1-1/8" tip and 2 1/2" fog nozzle
GPM and FL for solid stream nozzle 1-1/8" tip, 3" line
266 GPM / 6 psi
GPM and FL for 2-1/2" fog nozzle, 3" line
250 GPM / 5 psi
GPM for SM-20
150 GPM
GPM for SM-30
200 GPM
FL per 100 ft of 1-3/4" hose with SM-20
24 psi
FL per 100 ft of 1-3/4" with SM-30
38 psi
FL for wye
10 psi
Recommend pressure for 250 ft of preconnected 1-3/4" with SM-20
161 psi
Recommend pressure for 200 ft of preconnected 1-3/4" with SM-30
175 psi
FL per 100 ft of 3" hose flowing 150 GPM
2 psi
FL per 100 ft of 3" hose flowing 200 GPM
3 psi
FL per 100 ft of 3" hose flowing 300 GPM
7 psi
FL per 100 ft of 3" hose flowing 350 GPM
10 psi
FL per 100 ft of 3" hose flowing 400 GPM
13 psi
Manufacturer of fog nozzles
Elkhart Brass Co.
Manufacturer of 1" nozzles
Akron Brass Co.
NP for 1" fog nozzle
100 psi
GPM for 1" fog nozzles (booster hose)
13 - 60 GPM
NP for solid stream tips on master stream
80 psi
NP for fog nozzle on master stream
100 psi
FL for portable monitor set or deck gun
25 psi
NP for cellar nozzle
100 psi
GPM for cellar nozzle
260 GPM
FL for cellar nozzle pipe
10 psi
Diameter of water distribution for cellar nozzle
55 ft
FL for stand pipe system
25 psi
FL for each additional floor for a standpipe system
5 psi
Psi of Sprinkler System
Always 150 psi
Recommended NP for fog nozzle
100 psi
Recommended NP for 3" handline solid stream nozzle
50 psi
Recommended pressure for Quints
200 psi
NP for quint solid stream nozzle
80 psi
NP for quint fog stream nozzle
100 psi
NP for solid nozzle for deck gun or portable monitor
80 psi
NP for fog nozzle on deck gun or portable monitor
100 psi
Recommended pressure for foam eductors
200 psi
Discharge pressure for source truck and relay trucks for relay pumping
175 psi
FL for a reducer
10 psi
GPM for 1-1/2" tip on a monitor
598
GPM for 1-3/4" tip on a monitor
814
GPM for 2" tip on a monitor
1063
Foam eductor on Ladder 12 and GPM
Akron 3095 - 95 GPM
FL per 100' of 3" for the cellar nozzle
5 psi
Maximum hose length for Foam Eductor
250'
0-10% drop
3 x first line
11-15% drop
2 x first line
16-25% drop
1 x first line
Equation to find % drop
[(Static pressure - Residual pressure) x 100] รท Static pressure
GPM for 1000' of 3" discharge line for relay pumping
440 GPM
Reasons not to adjust to 175 psi during relay pumping
Intake drops below 20 psi, throttling up does not increase discharge pressure, or throttling up does not increase engine rpm
FL per 100' of 3" line flowing 100 GPM
1 psi
FL per 100 ft of booster line
8 psi
Elevation compensation
+/- 5 psi for every 10% change