API 510 Who Does It?

  1. Who responds to any inspection results that require corrective action?
    Owner/user
  2. Who determines to include 510 exempted vessels in the inspection program?
    Owner/user
  3. Who has the overall responsibility of complying with API 510?
    Owner/user
  4. Who is responsible to develop a QA inspection and repair management system?
    Owner/user
  5. Who is required to take an annual Jaeger J-1 eye test?
    Inspector
  6. Who is responsible to develop an effective MOC process?
    Owner/user
  7. Who is responsible to develop a program for Integrity Operating Windows?
    Owner/user
  8. During repairs and alterations, who is responsible for quality control?
    Repair organization
  9. Who assures the owner that testing, inspection, repairs, and examinations meet code? (TIRE)
    Inspector
  10. Who is directly involved in visual inspection activities?
    Inspector
  11. Who evaluates and accepts NDE examination results?
    Inspector
  12. Who makes recommendations for repairs, replacements, or fitness for continued service?
    Inspector
  13. Who performs NDE in accordance with specs?
    NDE Examiner
  14. Who determines qualification requirements for persons performing NDE?
    Owner/user
  15. Who maintains examiner's certification records?
    NDE Tech's employer
  16. Who notifies inspector or engineer of vessel integrity issues?
    EVERYONE
  17. Who establishes a tracking system for inspection audit findings?
    Owner/user
  18. Who develops the inspection plan for vessels and relief devices?
    Inspector OR engineer
  19. Who chooses to conduct RBI assessments?
    Owner/user
  20. Who reviews vessel history prior to inspections?
    Inspector
  21. Who familiarizes themselves with characteristics and causes of potential damage mechanisms?
    Inspector
  22. Who approves deviations from an inspection plan?
    Inspector OR engineer
  23. Who performs the internal inspection?
    Inspector
  24. Who assists with the internal inspection?
    Qualified others
  25. Who determines whether it is necessary to remove deposits or linings?
    Inspector AND corrosion specialist
  26. Who performs on-stream inspections?
    Inspector OR NDE examiner
  27. Who approves on-stream inspection work performed by examiners?
    Inspector
  28. Who specifies training requirements for non-AI's who perform external inspections?
    Owner/user
  29. Who accepts non-Inspectors to perform externals?
    Inspector
  30. Who notifies the inspector of any vessel deterioration found?
    All others
  31. Who performs external inspections?
    Inspector OR qualified others
  32. Who takes thickness measurements?
    Inspector OR NDE examiner
  33. Who reviews corrosion data for possible anomalies?
    Inspector
  34. Who reviews corrosion data if short term corrosion rates vary significantly?
    Inspector AND corrosion specialist
  35. Who assures those taking thickness measurements are trained and qualified?
    Owner/user
  36. Who should be aware of CUI suspect areas and that CUI is unpredictable?
    Inspector
  37. Who should be aware that CUI can be localized and that doing UT's during an Internal may be unsuccessful?
    Inspector
  38. Who determines locations of CML's for vessels with localized corrosion?
    Corrosion specialist
  39. Who is involved if the number of CML's will be significantly reduced or eliminated?
    Corrosion specialist
  40. Who determines the type of expected damage and selects an NDE method?
    Inspector AND corrosion specialist/engineer
  41. Specific Industry - Qualified UT angle beam examiners when needed?
    Owner/user
  42. During NDE, who should be aware of sources of measurement inaccuracies?
    Inspector AND NDE examiner
  43. Who reviews use of a component pressure test in lieu of complete vessel hydro?
    Engineer
  44. Who determines the pressure for tightness test (non-code test)?
    Owner/user
  45. During a hydro of 300 SS, who verifies the water quality and that the vessel is drained and dried?
    Inspector
  46. Who reviews potential risks of a pneumatic pressure test?
    Engineer
  47. Who develops pneumatic pressure test procedures?
    Engineer
  48. Who approves substituting NDE for a pressure test after an alteration or major repair?
    Inspector AND engineer
  49. Who determines if a pressure test is needed after a non-major repair?
    Inspector
  50. Who verifies new materials for repairs and alterations comply with those specified?
    Inspector
  51. Who PMIs new materials during repairs and alterations?
    Inspector OR examiners
  52. Who determines the sampling percentage when verifying new materials?
    Inspector OR owner
  53. Who selects the amount of additional PMI to do when the wrong material is found in an existing vessel?
    Inspector
  54. Who assess preferential corrosion in welds?
    Inspector
  55. Who assess crack like flaws and environmental cracking?
    Engineer OR Corrosion specialist
  56. Who inspects new vessels at the time of installation?
    Inspector
  57. When the vessel owner and location change, who checks that adequate documentation is provided?
    Inspector
  58. Who determines the external inspection interval?
    Inspector OR engineer
  59. Every 10 years, who reviews and approves RBI assessments with intervals beyond 10 years?
    Inspector AND engineer
  60. Who determines the external inspection requirements for retired by in place equipment
    Owner
  61. Who determines the internal/on-stream inspection interval?
    Inspector OR engineer
  62. Who approves the use of on-stream inspection in lieu of internal?
    Inspector
  63. Who maintains a fully documented QA process?
    PRD repair organization
  64. Who maintains a fully documented training program?
    PRD repair organization
  65. Who determines the relief device interval?
    Inspector OR engineer
  66. Who approves deferral of inspection tasks?
    Inspector AND owner
  67. Who is able to defer relief device interval (lesser of 10% or 6 months) without other approval?
    Inspector
  68. Who approves deferral of inspection repair recommendations?
    Inspector AND inspection supervisor
  69. Who changes or deletes inspection recommendations?
    Engineer OR inspection supervisor
  70. CONFLICT - Who selects which corrosion rate (short vs long) reflects the current conditions?
    • Inspector
    • Inspector AND corrosion specialist
  71. Who estimates corrosion rates for a new vessel or a vessel with a change of service?
    Corrosion specialist
  72. Who approves thickness measuring procedure for MAWP calc?
    Inspector
  73. Who uses Sect VIII div 2 for evaluation of pitting or LTAs?
    Engineer
  74. Who considers increasing the vessel required thickness for high consequence services?
    Engineer
  75. Who maintains vessel and relief device records?
    Owner
  76. Who has access to operating and maintenance records that affect vessel integrity?
    Inspector
  77. Who prepares equipment repair plans?
    Inspector OR engineer
  78. Who authorizes all equipment repairs? (Excluding Sect VIII Div II)
    Inspector
  79. Who authorizes all repairs to Div 2 vessels?
    Inspector AND engineer
  80. Who authorizes all alterations?
    Inspector AND engineer
  81. Who designates the hold point during repairs and alterations?
    Inspector
  82. Who provides general authorization of limited or routine repairs?
    Inspector
  83. During repairs, who approves all methods of design, materials, WPSs, NDE, and testing?
    Inspector OR engineeer
  84. For major repairs, temporary repairs, or alterations, who approves the methods, materials, WPS, NDE, and testing?
    Engineer AND inspector
  85. Who approves all repair and alteration work at hold points?
    Inspector
  86. Who approves all repair and alteration work at completion of work?
    Inspector
  87. Who approves all nozzle installations?
    Engineer
  88. During repairs and alterations, who determines if PMI is required due to questionable material documents?
    Inspector
  89. Who must be satisfied that the temporary repair is adequate for vessel continued service?
    Inspector AND engineer
  90. Who allows temporary welded repairs to remain in place past "next opportunity"?
    Inspector AND engineer
  91. Who determines if a crack will not propagate from under a fillet weld patch?
    Engineer
  92. Who approves the use of fillet-welded patch repairs?
    Inspector AND engineer
  93. Who approves the design and documentation off full encirclement lap band repairs?
    Inspector AND engineer
  94. Who determines if a crack will not propgate from under a full encirclement ap patch?
    Engineer
  95. Who authorizes the repair welding of cracks at stress concentration points?
    Engineer
  96. For insert plate repairs, who approves the use of NDE procedures as an alternate to RT?
    Inspector
  97. Who reviews the weld spacing  when installing an insert place?
    Engineer
  98. Who reviews and approves the repair procedures for SS cladding?
    Inspector AND engineer
  99. For a repair plan of welding SS clad or overlay, who considers atomic hydrogen mitigation?
    Engineer
  100. Who monitors the repairs made to SS cladding/overlay?
    Inspector
  101. Who uses welders and WPS's qualified to Sect IX or specified construction code?
    Repair organization
  102. Who verified that welding is done within the welders range and WPS range?
    Inspector
  103. Who maintains record of qualified WPS and WPQjQuery110104005759916109739_1504227147181
    Repair organization
  104. Who are welding records available to prior to welding?
    Inspector
  105. Who approves exceptions to preheat temperatures?
    Engineer
  106. Who monitors preheat temperatures?
    Inspector
  107. Who develops a procedure for local PWHT in lieu of a full encirclement PWHT?
    Engineer
  108. Who reviews the use of preheat in lieu of PWHT?
    Engineer
  109. WHo reviews the use of controlled deposit welding in lieu of PWHT?
    Engineer
  110. Who verifies that PWHT alternatives used are in compliance with specs and code?
    Inspector
  111. Who sets NDE acceptance standards after welding is complete?
    Inspector OR construction code
  112. WHo approves the use of alternate NDE methods after repairs and alterations?
    Inspector AND engineer
  113. Who performs calculations for rerates?
    Engineer OR manufacturer/other?
  114. Vessel rerates must be acceptable to who?
    Engineer
Author
Gibby
ID
333790
Card Set
API 510 Who Does It?
Description
API 510 Who Does It?