Emergency Shutdown on Deck
- 1) Condition Levers - FUEL CUTOFF
- - If confirmed/suspected fire or fuel leak, continue checklist
- - Otherwise, secure using Secure Checklist
- 2) Firewall Valves - CLOSED
- 3) Boost Pumps - OFF
- 4) Fire Extinguisher - AS REQUIRED
- 5) Aux Bat Switch - OFF
- 6) Gang Bar - Off
- 7) Evacuate Aircraft
-
Abnormal Start
- 1) Condition Lever - FUEL CUTOFF
- - Note decrease below 790°C
- 2) Starter - STARTER ONLY
- - for the remainder of the 40 seconds)
- 3) Starter - OFF (at 40 seconds)
-
Aborting Takeoff
- 1) Announce "ABORT"
- 2) Power Levers - IDLE
- 3) Reverse - AS REQUIRED
- 4) Brakes - AS REQUIRED
- 5) Condition Levers - FUEL CUTOFF
- 6) Firewall Valves - CLOSED
- 7) Boost Pumps - OFF
- 8) Fire extinguisher(s) - AS REQUIRED
- 9) Aux Batt Switch - OFF
- 10) Gang Bar - OFF
- 11) Evacuate Aircraft
-
Engine Failure After Takeoff
- 1) Power - AS REQUIRED
- 2) Gear - UP
- 3) Airspeed - AS REQUIRED (Vxse or Vyse)
- 4) Emergency Engine Shutdown - EXECUTE
-
EGPWS Pull Up Warning (IMC or at Night)
- 1) Wings - LEVEL
- 2) Power - MAX ALLOWABLE
- 3) Pitch - AS REQUIRED TO SET AND MAINTAIN Vx
- 4) Flaps - APPROACH (unless already up)
- 5) Gear - UP
- 6) Flaps - UP
- 7) Props - 1900 RPM
- 8) Continue climb at Vx until all visual and voice warnings cease
-
Low Altitude Windshear
- 1) Power - MAXIMUM ALLOWABLE
- 2) Attitude - SET AND HOLD APPROX 15° NOSE UP
- 3) Gear - UP
- 4) Flaps - MAINTAIN CURRENT SETTING
-
Spin/Out of Control Flight Recovery
- 1) Power Levers - IDLE
- 2) Rudder - FULL DEFLECTION OPPOSITE DIRECTION OF TURN NEEDLE
- 3) Control Wheel - RAPIDLY FORWARD
- 4) Rudder - NEUTRALIZE AFTER ROTATION STOPS
- 5) Control Wheel - PULL OUT OF DIVE BY EXERTING SMOOTH, STEADY BACK PRESSURE
-
Windmilling Airstart
- 1) Power Lever (Failed Engine) - IDLE
- 2) Prop Lever (Failed Engine) - FULL FORWARD
- 3) Condition Lever (Failed Engine) - FUEL CUTOFF
- 4) Firewall Valve - OPEN
- 5) Auto-ignition - ARMED
- 6) Condition Lever - LOW IDLE
- 7) Power - AS REQUIRED
-
Emergency Shutdown Checklist
- 1) Power Lever - IDLE
- 2) Prop Lever - FEATHER
- 3) Condition Lever - FUEL CUTOFF
- - If prop fails to feather, alternate feathering checklist
- - If confirmed/suspected fire or fuel leak, continue steps 4-6.
- 4) Firewall - CLOSED
- 5) Fire Extinguisher - AS REQUIRED
- 6) Bleed Air - CLOSED
-
Single-Engine Waveoff/Missed Approach
- 1) Power - MAX ALLOWABLE, ESTABLISH POSITIVE RATE OF CLIMB (Vxse minimum)
- 2) Flaps - APPROACH (unless already up)
- 3) Gear - UP
- 4) Flaps - UP
- 5) Prop - 1900 RPM
-
Jammed Power Lever
- 1) Condition Lever - FUEL CUTOFF
- 2) Emergency Shutdown Checklist - EXECUTE
-
Fuel Leaks
- 1) Condition Lever - FUEL CUTOFF
- 2) Emergency Shutdown Checklist - EXECUTE
-
Primary Governor Failure/Malfunction
- 1) Attempt to adjust prop RPM to normal operating range
- 2) Power Lever - IDLE
- 3) Prop Lever - FEATHER
- 4) Alternate Prop Feathering Checklist - AS REQUIRED
-
Generator Failure
- 1) Generator - OFF, RESET MOMENTARILY, THEN ON
- - If generator will not reset:
- 2) Generator - OFF
- 3) Current Limiter (Battery Ammeter) - CHECKED
-
Smoke and Fume Elimination
- 1) Oxygen masks/MIC switches (100%) - AS REQUIRED
- 2) Pressurization - DUMP
-
Explosive Decompression
- 1) Oxygen masks/MIC switches (100%) - AS REQUIRED
- 2) Descend - AS REQUIRED
-
Smoke/Fire of Unknown Origin
- 1) Crew - ALERTED
- 2) Cabin Temperature mode - OFF
- 3) Vent Blower - AUTO
- 4) Oxygen masks/MIC switches (100%) - AS REQUIRED
-
Emergency Descent Procedure
- 1) Power Levers - IDLE
- 2) Props - FULL FORWARD
- 3) Flaps - AS REQUIRED
- 4) Landing Gear - AS REQUIRED
- 5) Airspeed - AS REQUIRED
- 6) Windshield Heat - AS REQUIRED
|
|