LCS 2 COMP EOCC

  1. Loss of Ship Service Diesel Generator (MLSSG) # of Controlling/Immediate Actions
    • 6 (A-F) Controlling Actions
    • 10 (A-J) Immediate Actions
  2. Loss of Ship Service Diesel Generator (MLSSG) Controlling Actions
    • NOTE: When an alarm condition exists that does not cause an automatic emergency stop, proceed as follows
    • A. RCO report alarm condition to OOD and order CRT to man affected space
    • B. When ordered, CRT man affected space
    • C. CRT report to RCO Manned & Ready
    • D. RCO start standby SSDG & parallel to the bus
    • E. RCO open generator breaker for affected SSDG and stop affected SSDG
    • F. RCO report to OOD "Loss of No_SSDG. No_SSDG started and paralleled to the bus"
  3. Loss of Ship Service Diesel Generator (MLSSG) Immediate Actions
    • WARNING: WHEN FUEL OIL LEAK IS PRESENT, PROCEED IMMEDIATELY TO ID NO. MMFOL
    • A. RCO report to OOD "Loss of No_ SSDG"
    • B. When required, RCO E-Stop affected SSDG. Ensure gen breaker opens
    • C. RCO ensures standby SSDG starts
    • D. RCO parallel standby SSDG to bus
    • E. RCO order CRT to man space
    • F. When ordered, CRT man space
    • G. CRT report to RCO Manned & Ready
    • H. CRT visually inspect for fuel/lube/coolant/seawater leaks
    • I. When required, CRT man F/F equipment & report to RCO "FF Equipment manned"
    • J. RCO report to OOD "Loss of no_ SSDG. No SSDG E-Stopped. No _ SSDG started and paralleled to bus. When required "FF Equipment Manned"
  4. Ship Service Diesel Generator Governor Malfunction (MDGGM) # of Immediate Actions
    9
  5. Ship Service Diesel Generator Governor Malfunction (MDGGM) Immediate Actions
    • A. RCO split electrical plant, determine and E-stop affected SSDG
    • B. RCO start standby SSDG
    • C. RCO close standby SSDG breaker
    • D. RCO parallel unaffected with standby SSDG
    • E. RCO report to OOD "Governor Malfunction No_SSDG, No_SSDG stopped. No_SSDG started & paralleled to bus"
    • F. RCO order CRT to man affected space
    • G. When ordered, CRT man affected space
    • H. CRT report to RCO manned & ready
  6. Ship Service Diesel Generator Governor Malfunction (MDGGM) Symptoms & Indications
    • 1. Excessive hunting of governor or fluctuating engine speed
    • 2. Engine fails to respond to load change
    • 3. Engine overspeeds or surges
  7. MLSSG Symptoms/Indications
    • Loss of L/O Pressure
    • Loss of F/O Pressure
    • High Coolant Temperature
  8. MLSSG Possible Effects
    • Loss of SSDG
    • Reduced generator capacity
    • Personnel injury
Author