Diagram memorization:
MPDE Service Tank Fill Valve
EM Type
FT-V-75
Diagram memorization:
MPDE Sounding Tube
TV-V-15
Diagram Memorization: Valve coming out of Service Tank
EM Type
GFS-V-70
Followed by a swing check valve
MPDE Fuel Delivery Pump driven by
MPDE accessory gear train
Testing Requirements: Fuel from commercial supplier or emergency fuel
Flashpoint (NAVIFLASH) test
: 140F min flashpoint
Record API Gravity
BS & W
: .05% MAX
Testing Requirements: Deck Connection
Start/Midpoint/Finish
: BS&W .1% MAX
Every 15 mins
: Clear & Bright
Testing Requirements: Ship's Storage F/O
Prior to U/W, Weekly
: WIP test from Stripping Discharge
Weekly
: Record API Gravity from Stripping Discharge
Testing Requirements: Fuel Service Tank
Within 8 hours before use
: Thief/Bottom Sample C&B Test
Weekly
: WIP test
*Aligned to generators on autostartup
: Test daily when not in use
Testing Requirements: Transfer Filter Separator
Discharge sample 5 mins after transfer initiated
:
C&B (DIESEL)
40ppm/2.64mg/L CCFD (GT)
Testing Requirements: FOCM
Discharge sample 5 mins after transfer initiate + every 8 hours:
40ppm/2.64mg/L CCFD