API 653 Baytech closed book practice exam missed questions part 3

  1. Special consideration must be given to what area of the tank bottom with regard to thick-film lining?
    The covering at the transition from the tank bottom to the shell
  2. A service life of          years should be expected from a properly selected and applied lining system.
    10 to 20 yrs
  3. When a tank is of welded construction and has significant distortion, weld seams may crack. When cracking is suspected, what is the preferred method of NDE
    MT
  4. An impressed current cathodic system is installed; the installing contractor connected the positive connection of the rectifier to the tank. Is this a satisfactory installation?
    No the connection is incorrect, the tank bottom will now act as the anode resulting in rapid corrosion of the tank bottom
  5. The base metal goes into solution (corrodes) by releasing electrons and forming positive metal ions. This statement describes what takes place at what component of a corrosion cell?
    The anode
  6. How can the life of an impressed current anode be increased?
    Properly installing the back fill material
  7. The radiographic film for all junctions of vertical and horizontal joints in new fabrication shall show @ least         of weld length on each side of the vertical intersection.
    2"
  8. What are the 2 types of cathodic protection systems most commonly used?
    Galvanic anode system and impressed current system
  9. Atmospheric tanks that are designed for not more than 0.5 psig over the static pressure of the liquid contained in the tank are normally tested
    by filling the tank with water
  10. Of the following, which is not an option available to the owner/operator if it is not possible to satisfy the requirements of minimum thickness calculations for a welded tank?



    D) Reduce the fill rate so the tank fills slower and applies pressure gradually
  11. In placing the anodes, how is better current distribution and more uniform polarization obtained?
    By distributing the anodes uniformly around the tank or under the tank for new construction
  12. API 650 covers the design, materials, fabrication, erection, and testing of above ground steel storage tanks. What is the maximum internal pressure for tanks not covered by appendix F of this standard?
    Maximum pressure shall not exceed the weight of the roof plates
  13. According to API 650, tack welds
    Are not considered as having any strength value in the finished structure
Author
egf4201
ID
329900
Card Set
API 653 Baytech closed book practice exam missed questions part 3
Description
API 653 Baytech closed book practice exam missed questions part 3
Updated