Which of the following is an advantage of the galvanic cathodic protection system?
A) Annual maintenance costs are generally low
Hot taps are permitted
only in the liquid section of tank
Repaired or replaced bottom welds shall be examined with either a vacuum box or by using
a tracer gas test
Which of the following does NOT increase the risk of brittle failure?
C) Change to a product with increased viscosity
Which type of external floating-roof is the most susceptible to sinking
Pan
The welding position 4G is a
overhead plate grove weld
If an atmospheric tank is air tested, the pressure should NOT exceed
2" of water
Which of the following new welds does NOT need to be examined by magnetic particle or liquid penetrant methods?
C) The insert plate-to-shell welds
During a tank reconstruction, a 0.750" shell course can be dismantled by cutting
a minimum of 6" away from the existing weld
Fatigue will NOT occur in carbon steel if stresses are below the
endurance limit
The grain structure of weld metal is most similar to that found in
castings
Which of the following is NOT a significant factor in galvanic corrosion?
A) Stray AC currents
Which welding discontinuity is located @ the toe of the weld?
Overlap
A tank with cathodic protection has a second bottom added above the old floor. This tank may:
experience accelerated corrosion on the upper floor
Dry pyrophoric material can cause
ignition
When adding new shell penetrations, when shall an insert plate be used
For all penetrations that are greater than 2 NPS, and the shell plate exceeds 1/2", and the shell plate material does not meet the current design metal temp
When removing a weld defect, cavities resulting from gouging or grinding shall be examined visually and by the
UT method
A major cause of tank lining failures is inadequate
curing time
If substituting an air-test for a tank hydrotest the air pressure should not exceed
2" of water
Which of the following is an advantage with an impressed current cathodic protection system (as compared to a galvanic system)?
C) Effective for tanks of all sizes
During a repair or alteration, new welds in shell plate greater than 1" thick shall be
examined by radiographic, visual, and either MT or PT
Pitting is found on the shell. Corrective action must take place when the
remaining thickness is less than 50% t-min
An impressed current cathodic protection system was sized for a specific tank. At the first inspection it was determined that the bottom side corrosion rate was extremely high. What is the likely cause?
Leads on the rectifier are reversed
What is a common problem for flame arrestors
Internal screens get plugged
When walking on the roof of a cone roof tank, the inspector should
walk on the lap joints as much as possible
A statistical method is used to determine the probable minimum remaining thickness. Typically how much of the floor is scanned to gather info for the statistical analysis
0.2-10%
During a major tank repair, the top shell course is replaced with new material. The new shell course is 0.250". How many RT's are required in the new vertical welds?
1 in every 100' of vertical weld
Author
egf4201
ID
329843
Card Set
API 653 Closed Book Practice Exam missed questions
Description