Chip detector warning
- *PCL - minimum necessary to intercept ELP; avoid unnecessary PCL movements
- *PEL - execute
-
Oil System Malfunction
- IF ONLY AMBER OIL PX CAUTION ILLUMINATES:
- *Terminate Maneuver
- *Check oil pressure; if oil pressure is normal, continue operations
- IF RED OIL PX WARNING ILLUMINATES AND/OR AMBER OIL PX CAUTION REMAINS ILLUMINATED FOR 5 SECONDS:
- *PCL - minimum necessary to intercept ELP; avoid unnecessary PCL movement
- PEL - execute
-
Generator Inoperative
- Starter switch - NORM (both)
- GEN switch - on (front or back)
- GEN RESET switch - Depress and hold for a minimum of 1 second
- IF GENERATOR REMAINS INOPERATIVE (DC VOLTMETER BELOW 25 VOLTS AND AMMETER DISCHARGING):
- Descent below 10,000 MSL - initiate (as req)
- GEN switch - OFF (both)
- BUS TIE switch - open
- Land as soon as practical
-
Generator Bus Inoperative
- BUS TIE switch - NORM
- Land as soon as practical
-
Battery Bus Inoperative
- Descent below 10,000 MSL - initiate (as req)
- BUS TIE switch - OPEN
- AUX BAT switch - ON
- Standby VHF - ON
- Land as soon as practical
-
Dual IAC Failure
- Backup flight instrument - ref as req
- NORM/REPEAT switch (both UFCPs) - Norm (both)
- IAC1 and IAC2 circuit breakers (left front and right front) - check, reset if open
- IF BOTH IAC REMAIN FAILED
- Land as soon as practical
-
Singe IAC Failure
- Backup flight instruments - ref as req
- IAC circuit breaker (1 left, 2 right) - check, reset if open
- Land as soon as practical
-
IRS Failure
- Backup flight instruments- ref as req
- IRS circuit breaker (left and right front console) - Check, reset if open
- Place aircraft in straight and level, unaccelerated flight and monitor alignment status
- Land as soon as practical
-
UFCP Failure
UFCP circuit breaker (left front console or left rear console) - check, reset if open
-
Backup Flight Instrument
- Straight and level unaccelerated
- SSTBY INST circuit breaker - check, reset if open
- AFT STBY circuit breaker - check, reset if open
- IF DISPLAY DOES NOT RETURN
- Land as soon as practical
-
MFD Failure
- NORM/REPEAT in failed cockpit - REPEAT
- MFD circuit breakers - check, reset if open
- Backup flight instrument - ref as req
-
Low Fuel PX
- PEL - execute
- Boost Pump switch - ON
|
|