Combi boiler shutting down irregularly.
Vent cap closed.
Seized float/needle valve due to rust/sludge/scale.
Boiler Cycling
Sludge/scale build up in main heat exchanger.
Boiler thermostat failed.
No means of providing boiler interlock.
Combi Boiler Shuts Down/Lockout before Demand is Satisfied.
Additional radiators fitted with thermostatic radiator valves.
additional thermostatic valves added.
last/highest radiator not reaching temperature.
fan is faulty/failing.
no automatic by-pass valve fitted.
Room/programmable room thermostat set too low or incorrectly sited.
Solenoid is faulty when hot.
Reverse polarity. L&N connections wrong way around.
Boiler lockout
Condensate formed ice plug in pipe work.
Condensate not running away.
Combi boiler fires ok, when demand stops, goes. To lockout.
Pump or fan over-run has failed, overheat thermostat operated, combi goes to lockout.
Combi Boiler Shut Down (Overheat)
Expansion vessel faulty.
Air trapped in system.
Water leak.
By-pass valve faulty.
Air pressure switch faulty.
Pump failing/failed.
Pump fitted the wrong way around.
Sludge/scale built up in heat exchanger and kettling.
Thermistor loosing calibration/failed.
Overheat thermostat faulty.
high limit thermostat faulty.
thermostat phial incorrectly positioned.
Gas rate too high.
Faulty gas valve.
Solenoid sticking in on position.
Gas regulator at gas meter faulty.
undersize gas supply pipe work.
FSD incorrectly positioned/faulty.