giusp - reports of fumes

The flashcards below were created by user zenken79 on FreezingBlue Flashcards.

  1. Reports of Fumes.

    Co detector alarm sounds or fumes reported. Flued appliances.
    Spillage and/or leakage of products of combustion occurring, or signs of occurrence (with no evidence that the problem has been corrected).
    ID
  2. Reports of Fumes.

    Flueless appliances.
    Evidence of poor combustion occurring.
    ID
  3. Reports of Fumes.

    Flue terminations located in positions which could allow combustion products to enter properties e.g. in close proximity to windows, doors and air vents.
    ID
  4. Reports of Fumes.

    Following an assessment, the concentration of combustion products entering the premises is outside the acceptable limits of BS7967 e.g. CO greater than 10ppm and rising.
    ID
Author
ID
312536
Card Set
giusp - reports of fumes
Description
giusp - reports of fumes
Updated
Show Answers