Home
Flashcards
Preview
API 510 Data Sheets ( Temperatures)
Home
Get App
Take Quiz
Create
Welding- base metal temp where welding is not recommended
< 0°F
Welding- Base metal temp when pre-heat to 60 °F is recommended
0-32°F
Corrosion-CUI affects Carbon steel and low alloy (temp range)
10-350°F
UT calibration- calibration block must be within what temp of the part to be examined
25°F
NDE- standard temp range for a PT exam
40-125°F
Corrosion- temp where cooling water corrosion starts to significantly increase
140°F
Corrosion- Temp where chloride stress corrosion cracking becomes a concern
>140°F
Corrosion- CUI affects Austenitic SS (temp range)
140-400°F
NDE- special procedures are needed for UT thickness readings
≥150°F
Corrosion- temp when high strength caustic causes serious corrosion in CS and 300 SS
>150°F
Corrosion- temp swings that can cause thermal fatigue
+/- 200°F
Corrosion- most aggressive CUI temp range
212-250°F
Welding- Min pre-heat temp when pre-heat is substituted for PWHT
300°F
Welding-Min pre-heat temp when a local PWHT is used in lieu of a full encirclement PWHT
300°F
Corrosion- starting temp for Sulfidation on CS
500°F
Corrosion- temper embrittlement for low chromes (range)
650-1100°F
Inspection- if vessel operating temp is above this consult a corrosion specialist when developing an inspection plan
750°F
Corrosion- if operating temp is above this, check for creep in cat reformer equipment
>900°F
NDE- MAX temp for UT readings
1000°F
Materials- carbon steel PWHT temp
1100°F
Testing- minimum base metal temp during hydro testing vessels less than 2" thick
MDMT + 10°F
Testing- Min base metal temp during hydro testing vessels greater than 2" thick
MDMT + 30°F
Author
egf4201
ID
308982
Card Set
API 510 Data Sheets ( Temperatures)
Description
API 510 Data Sheets ( Temperatures)
Updated
2015-10-04T18:28:46Z
Show Answers