NDE- minimum time an examiner should be in a darkened area prior to using a black light for MT & PT exams
5 minutes
testing- minimum duration for a pressure test
10 minutes
NDE- final interpretation of a PT exam after application of developer (time range)
10-60 minutes
testing- minimum duration of hydro to evaluate integrity of buried pipe
8 hours
NDE- max calibrating interval - MT permanent magnet yoke
daily
NDE- max calibrating interval- RT densitometer
90 days
maximum time for obtaining thickness readings when corrosion rate on new pipe is not known ( no other data available)
3 months
welding- max time a welder or welding operator maintains qualifications for a process without using that process
6 months
interval- suggested interval for above-grade visual survellance of buried pipe
6 months
NDE- max calibrating interval- electromagnetic mt yoke
1 year
NDE- maximum interval for a visual examiner's eye exam
1 year
NDE- max interval to calibrate pressure gauge used in testing
1 year
AI- length of time before an API 570 AI must recertify
3 year
Insp- max thickness inspection interval for an injection point
lesser of 3 yr or 1/2 life
Insp- max external inspection interval for class 1 & 2 piping
5 year
Insp- maximum interval for relief devices in fouling or corrosive service
5 year
Insp- suggested interval for close-interval potential survey of buried pipe with porr CP
5 year
Insp- suggested interval for evaluation of soil corrosivity for buried pipe with no CP
5 year
Insp- max thickness inspection interval for class 1 piping
lesser 5 year or 1/2 life
Insp- maximum interval for relief devices in non-fouling or non-corrosive service
10 years
Insp- minimum years of experience for owner's inspector during new fabrication
10 years
Insp- maximum external inspection interval for class 3 piping
10 years
Insp- maximum thickness inspection interval for class 2 & 3 piping
lesser 10 yr or 1/2 life
RBI- maximum interval for the RBI reassessment
per table 2
repairs- when should temporary welded pipe repairs be replaced
next oppurtunity
repairs- when shall non-welded repairs & temporary leak sealing devices and be removed and pipe repaired
next turnaround
NDE- max calibrating interval- check the light intensity of a black light used in a MT or PT exam
before & after use