design- mill tolerance for rolled and welded pipe
-0.010"
NDE- maximum length of crack, or incomplete fusion allowed on a new weld
0"
flanges- typical flange finish
125-250 micro-inch
flanges- when mating flanges, the maximum amount of unparallel allowed (per diameter of flange in feet)
1/16" per foot
flanges- max offset for bolt-holes for mating flanges
1/8"
welding- maximum allowed size of open discontinuity in a bend test
1/8"
preheat zone- distance from toe of weld
1"
PWHT zone- distance from toe of weld
1"
NDE- minimum distance beyond the area to be examined to clean a part when performing a MT examination
1"
NDE- minimum distance beyond the area to be examined to clean a part when performing a PT examination
1"
repairs- minmum radius of insert patch
1"
repairs- minimum radius of insert patch
1"
NDE- max diameter of CML exam point for lines < or equal to 10 nps
2"
NDE- max diameter of CML exam point for lines > 10 nps
3"
NDE- minimum lenght of spot RT
6"
welding- min length to RT/UT when qualifying a welder with test coupon or 1st production weld
6"
welding- minimum lenght of RT when qualifying a welding operator with a test coupon
6"
corrosion- soil-to-air area- distance in air from interface
6"
corrosion- distance to dig when inspecting for soil-to-air corrosion
6-12"
NDE- distance of eye-to-part to count as a visual exam
6-24"
corrosion- soil-to-air area0 distance in soil from interface
12"
NDE- minimum upstream limit of intensive examination of injection point circuit
12"
PWHT- min overlap for PWHT when using multiple heats
12"
welding- minimum length of RT/UT when qualifying a welding operator on first production weld
3'
underground- minimum length of buried pipe to expose when excavating for inspection
6-8'
repairs- maximum size of fillet weld patch on pipe
1/2 diameter
circuits- minimum upstream limit of injection point circuit
greater of 12" or 3 dia
NDE- minimum downstream limit of intensive examination for injection point circuit
10 daimeters
circuits- min downstream limit of injection point circuit
lesser of
:
1st direction change + 25', or
2nd direction change.