HOW MANY AMPS ARE ON THE PRIMARY SIDE OF A STEP DOWN TRANFORMER UNDER FULL LOAD
32 AMPS
SYMBOL FOR FULL WAVE RECTIFIER
WHAT IS THE RATING OF A SIGNAL MACHINE ALTERNATOR
75 KVA
WHAT RELAYS INDICATE A BUSS LOCKOUT
CA4 AND JD
A RELAY ON A SIGNAL MACHINE THAT BEGINS WITH A 1 MONITORS WHAT
GENERATOR SIDE.
WHAT MUST YOU DO BEFORE WORKING ON A TRANSFORMER
ISOLATE PRIMARY AND SECONDARY HIGH AND LOW SIDE
A RELAY ON A SIGNAL MACHINE THAT BEGINS WITH A 2 MONITORS WHAT
MONITORS THE MOTOR SIDE
HOW DO YOU CHECK VOLTAGE ON A BUSS
AT THE SECONDARY POTENTIAL FUSE. V AND VO ON THE TERMINAL BLOCK
THE DIFFERENCE BTWN THE FULL LOAD SPEED AND SYNC SPEED IS WHAT
SLIP OF THE MOTOR
WHAT IS THE ACCEPTABLE DI-ELECTRIC INSULATION VALUE OF OIL
26 KV
WHAT MUST YOU DO PRIOR TO WORKING ON THE SUBSTATION RAIL RETURN BUSS
APPLY THE PROPER GROUNDS
WHAT ALARM HAS THE PD OPEN THE LOW SIDE THEN THE HIGH SIDE
BTA
BELL TEMPERATURE ALARM
HOW MANY VOLTS AND AMPS IS A TROLLEY BREAKER RATED FOR
35 KV
1500 AMPS
WHAT IS THE RATIO OF A POTENTIAL TRANSFORMER
100:1
WHAT IS THE SIZE OF THE FUSE ON THE SECONDARY SIDE PF A POTENTIAL TRANSFORMER
6AMPS
WHAT PROVIDES THE POWER FOR THE SIGNAL LINE AND CHANGES THE FREQUENCY
SIGNAL MACHINE
WHEN IS IT SAFE THE WORK ON A CIRCUIT
WHEN IT IS TESTED DE-ENRGIZED AND GROUNDED
WHAT ARE THE HOT LEGS OF A CT
F FF
S SS
WHAT SIDE OF A STEP UP TRANSFORMER HAS MORE TURNS ON THE WINDINGS
SECONDARY
HOW MANY VOLTS IS THE THIRD RAIL
750 VDC
WHAT IS THE RATING OF THE PRIMARY FUSE ON A SERVICE TRANSFORMER
.5 AMPS
SYMBOL FOR A CT
what type of print is needed to replace or work on a test switch
R&C
RELAY AND CONTROL
AMTRAK STEP DOWN POWER TRANSFORMER ARE WHAT POLARITY
SUBTRACTIVE
HOW DO YOU MEASURE VOLTAGE WITH A MULTI METER
IN PARALLEL
WHAT MUST BE DONE TO A LIGHTNINING ARRESTOR PRIOR TO WORKING ON IT
DISCHARGE
AC TO DC
RECTIFIER
DC TO AC
INVERTER
WHAT NEEDS TO BE OPENED FOR A TRANSFORMER CLEARANCE
HIGH AND LOW SIDE
THE LIGHNING ARRESTOR IS LOCATED BTWN WHAT 2 DISCONNECTS
F AND T DISC
WHAT MUST BE DONE PRIOR TO WORKING ON A VACUUM CIRCUIT BREAKER
DISCHARGE THE SPRING FIRST
WHAT IS STATION CONTROL VOLTAGE
132 VDC
WHAT CANNOT BE TICK TESTED
TRANSMISSION LINE
WHAT PROPERTY EXISTS WHEN THE RELATIVE POSITION OF 2 INDUCTORS CAUSES THE MAGNETIC LINES OF FORCE TO LINE WITH THE TURNS OF ANOTHER
MUTUAL INDUCTION
AT WHAT VOLTAGE DO YOU NEED A CLEARANCE
480 AND ABOVE
WHAT IS THE FIRST THING YOU DO IF YOU GET A HOT TICK
CALL THE PD
WHAT DOES THE 230 LOCKOUT PREVENT
AUTOCLOSURE OF THE SIGNAL FEEDER
THE CR IS SUPERVISED BY WHAT RELAY
AV RELAY
WHAT POLARITY IS THE SIGNAL TRANSFORMER
SUBTRACTIVE
WHAT TYPE OF RELAY RESPONDS TO EXPANDING BI-METAL
THERMAL
WHAT ALLOWS THE SEPERATION OF TROLLEY CIRCUITS AND CONTINUATION OF POWER
SECTION BREAK
WHAT IS THE FIRST THING YOU DO AFTER RECIEVING SWITCHING ORDERS FROM THE POWER DIRECTOR
REPEAT THEM
WRITE THEM DOWN
WHAT IS THE VOLTAGE AMD FREQUENCY OF A 152 CONTACTOR
480 VOLTS
100 HZ
SINGLE PHASE
WHAT IS A MEGGER USED FOR
TESTING THE INSULATION VALUE
WHAT IS THE SECONDARY VOLTAGE ON A HEATER STATION TRANFORMER
PRIMARY 12 KV
SECONDARY 480 V
WHAT TYPE OF RELAY INTRODUCES A DELAYED REACTION WHERE THE DELAY DECREASES AS THE OPERATING FORCE INCREASES
INVERSE TIME RELAY
WHAT DOES A CURRENT TRANSFORMER DO
STEPS DOWN AMPERAGE TO LEVEL THAT CAN BE MEASUERED
POWER TRANSFORMERS USED BY AMTRAK ARE WGAT CONFIGURATION
WYE DELTA