F50

  1. Standing water limit
    • > 12.7mm over >10%
    • T/O prohibited
  2. Is T/O allowed with a contaminated runway?
    • Contaminated is >3mm over >25%
    • T/O allowed but special tables req.
  3. Aircraft weight lims
    • MRW - 20865
    • MTOW - 20820
    • MLW - 19730
    • MZFW - 18600
  4. X-wind limitations
    • Dry - 33kts
    • Wet - 30kts
    • Standing water - 15kts
    • Downwind - 10kts
  5. Airspeed limits
    Vmo
    • <FL200 - 224KIAS
    • >FL200 - FL250 - linear decrease to 206KIAS
  6. Airspeed limits
    Va
    175Kts
  7. Airspeed limits
    Vturb
    165kts
  8. Airspeed limits
    Gear
    170kts
  9. Airspeed limits
    Flap
    • 5/10/15 - 180
    • 20/25 - 160
    • 35 - 140
  10. Limits with window heat inop
    • <10,000'
    • <18 deg TAT
    • Then speed max 180KIAS
  11. Instrument error
    ASI: 60-100 (4); 100-160 (5); 160-224 (6)

    Alt: 0' (40); 10,000' (115); 20,000' (180)
  12. In icing conditions, what is the restriction on flap 35?
    Do not select above 300' AGL
  13. What are the pressurisation limits?
    • Max differential - 5.45 psi
    • Relief valve - 5.7 psi
  14. Engine limitations.
    T/O max TQ
    92%
  15. Engine limitations.
    T/O ITT
    765 - 778 deg
  16. Engine limitations.
    GA max TQ
    102%
  17. Engine limitations.
    GA time limit
    10 min
  18. Engine limitations.
    MCT max TQ
    87.5%
  19. Engine limitations.
    CLB max TQ
    Unlim 100%

    10 min 102%
  20. Engine limitations.
    Start ITT
    • 840 - 20 sec
    • 950 - 5 sec
  21. Engine limitations.
    GA and MCT with Prop EC fault
    GA TQ 96%

    MCT TQ 82.5%
  22. Propeller limits.
    When stationary
    Not allowed between 65% - 90%
  23. Propeller limits.
    Prop EC fault
    Max TAS 220kts
  24. Max fuel capacity?
    4050kg
  25. Max fuel asymmetry?
    • 20820kg - 150kg diff
    • 19005kg - 500kg diff
  26. Max refuel/defuel pressure?
    refuel - 60 psi

    defuel - 11 psi
  27. Electrical system.
    DC/Emerg DC voltage
    26 - 31 v
  28. Electrical system.
    AC/Emerg AC voltage and freq
    115v +/- 3

    400hz +/- 4
  29. Electrical system.
    External AC volts and freq
    115v +/- 15

    400Hz +/- 15
  30. Electrical system.
    External DC voltage
    Battery - 24 - 32 v

    rectodyn - 24 - 29v
  31. Electrical system.
    Generator load, volt, freq
    • Load: cont 100%, 5min 113%, 5sec 150%
    • Volt: 115 +/-3
    • Freq: 400Hz +/- 4
  32. Electrical system.
    TRU load, voltage
    Load: cont 100%, 2min 133%, 5sec 300%

    Volt: 26 - 31v
  33. Electrical system.
    battery load and volts
    Load: +40 to -40

    Volts: 24 - 32v
  34. Altitude to select auto pilot on/off
    On - 400' AGL

    • Off:
    • ILS - 50'
    • Other - 200'
  35. Wx radar ground operations
    • Clear within 180 deg to 60m
    • No reflecting objects within 180m
    • Tilt not lower than 0 deg
Author
1261
ID
22958
Card Set
F50
Description
F50 co. procedures
Updated