CRJ Systems 2.txt

    • author "charlesincharge"
    • tags "fuel electric steering apu press "
    • description "systems"
    • fileName "CRJ Systems 2.txt"
    • freezingBlueDBID -1.0

    • Fuel
    • 200
    • Usable fuel, each wing
    • 4,760 lbs
  1. Fuel
    700/900
    Usable fuel, each wing
    7,492 lbs
  2. Fuel
    200
    Usable fuel, center tank
    4,998 lbs
  3. Fuel
    700/900
    Usable fuel, center tank
    4,610 lbs
  4. Fuel
    200
    Usable fuel, total
    14,518 lbs
  5. Fuel
    700/900
    Total fuel
    19,594 lbs
  6. Fuel
    All
    max imbalance
    800 lbs
  7. Fuel
    200
    Max imbalance, T/O
    800 lbs
  8. Fuel
    700/900
    Max imbalance, T/O
    300 lbs
  9. Fuel
    200
    Min for GA per wing
    450 lbs (amber)
  10. Fuel
    700/900
    Min for GA per wing
    600 lbs
  11. Fuel
    All
    Min Temp T/O
    +5*C
  12. Elec
    200
    Main Gen
    • to 35,000 ft: 30 kVA
    • >35,000 ft: 25 kVA
  13. Elec
    700/900
    Main Gen
    to 41,000 ft: 40 kVA
  14. Elec
    200
    APU Gen
    to 37,000 ft: 30 kVA
  15. Elec
    700/900
    APU Gen
    to 41,000 ft: 40 kVA
  16. Elec
    200
    Max Cont DC TRU
    100 A
  17. Elec
    700/900
    Max Cont DC TRU
    120 A
  18. Elec
    All
    GND Ops DC ONLY
    5 min
  19. Steering
    200
    Tiller
    70* L/R
  20. Steering
    700/900
    Tiller
    80* L/R
  21. Steering
    200
    Rudder
    5* L/R
  22. Steering
    700/900
    Rudder
    8* L/R
  23. APU
    All
    Min Temp Start
    -40*C
  24. APU
    200
    Max Ops Alt
    37,000 ft
  25. APU
    700/900
    Max Ops Alt
    41,000 ft
  26. APU
    200
    Max Start Alt
    30,000 ft
  27. APU
    700/900
    Max Start Alt
    37,000 ft
  28. APU
    200
    Max Alt Bleed use
    15,000 ft
  29. APU
    700/900
    Max Alt Bleed use
    25,000 ft
  30. APU
    200
    Max Alt Eng Start
    13,000 ft
  31. APU
    700/900
    Max Alt Eng Start
    21,000
  32. APU
    200
    Max Gen Load
    30 kVA
  33. APU
    700/900
    Max Gen Load
    40 kVA
  34. APU
    200
    Max speed Door Open with APU not operating
    300 KIAS
  35. APU
    700/900
    Max Speed Door Open with APU not operating
    220 KIAS
  36. APU
    200
    Start AC Batt
    • 2x30 sec ON - 20 min OFF
    • 2x30 sec ON - 40 min OFF
  37. APU
    200
    Start
    • 2x15 sec ON - 20 min OFF
    • 2x15 sec ON - 40 min OFF
  38. APU
    700/900
    Start
    Do not perform more than three start/start attempts in one hour.
  39. A/C
    All
    Max Diff
    8.7 psi
  40. A/C
    All
    Max Neg Diff
    -0.5 psi
  41. A/C
    All
    Taxi, T/O, LND Max diff
    0.1 psi
  42. A/C
    200
    Single Pack Ops to
    FL 250
  43. A/C
    700
    Single Pack Ops to
    FL 310
  44. A/C
    900
    Single pack Ops to
    FL 250
  45. A/C
    200
    Pack overheat
    88*C
  46. A/C
    200
    Pack overpressure
    >53 psi
  47. A/C
    All
    Cabin Alt Caution
    >8,500<10,000 ft
  48. A/C
    All
    Cabin Alt Warning
    >10,000 ft
  49. A/C
    200
    CPAM Pax O2
    14,000 +-500 ft
  50. A/C
    700/900
    CPAM PaxO2
    >=14,000 ft
  51. A/C
    All
    CPAM NoSmoFaSB
    10,000 ft
  52. A/C
    200
    EmDepr
    14,250+-750 ft
  53. A/C
    700/900
    Em Depr
    14,500+-500 ft
  54. A/C
    700/900
    EMER DEPRESS Switch
    prohibited above 15,000 ft
  55. A/C
    700/900
    Climb above FL300
    < 1500 FPM
Author
Charlesincharge
ID
204121
Card Set
CRJ Systems 2.txt
Description
crj
Updated