-
T/O
CONFIG
At least 1 of the 3 throttles must be at 82° Power Lever Angle and
Airplane is on the ground and 1 or more of the following:
- 1 of the 4 inboard airbrakes is not retracted 1 of the 4 slats is not extended
- Flaps are beyond the 22° position
- Horizontal stab is out of takeoff range (-3° through -7°)
- Autopilot is engaged
- Parking brake applied
- #2 brakes applied
-
REV
UNLOCK
Thrust reverser unlocked on ground or inflight with control handle in STOW position
- 1. Control actuator not locked. Or
- 2. Microswitch which indicates STOW position for RH or LH target door not closed
- 3. Secondary latch not locked
- Note: TRANSIT or DEPLOYED lights on instrument panel illuminate sequentially
-
CABIN
With aural warning: Cabin altitude higher than 10,000 +/- 500 feet
-
AP
Autopilot failed
Auto disengagement of autopilot & light illumination. Failure detected by AP internal monitoring circuit
Note: Light can be extinguished by again pressing AP DISENGAGE button on either control wheel
-
HOT BAT
Battery 1 and/or 2 overheat - internal temp of >150°F or 160°F with digital BAT TEMP indicator
NOTE: This light is in parallel with red light located on double BAT TEMP indicator
-
OIL 1 OIL 2 OIL 3
Oil pressure < 50 psi in associated engine
-
ENG 2 FAIL
Illuminates when either of following occurs:
- S-duct door is open
- Aircraft is on ground, #2 throttle is >84°, and #2 engine RPM is <85% with 15 second time delay
-
DOORS
Illuminates if any of the following conditions exist:
- Main cabin door unlocked
- Main cabin door handle not latched
- Baggage door is unlocked
- Aft compartment door unlocked, but monitored only on ground
-
AUTO
SLAT
Illuminates when either of folowing occurs:
- Failure of IAS disarm contacts that normally prevent auto extension of outboard slats at 270 KIAS or
- After takeoff if either ground flight relay remains in ground mode 5 seconds after takeoff. One of the autoslat system is not available in flight
-
COND'G
OVHT
Conditioned air overheat in distribution ducts
Temperature of air in cabin and/or cockpit supply duct > 85°C - 95°C
-
FLAP
ASYM
Flaps stop to move at same time light illuminates. Detection of LH and RH flap deflection asymmetry
- 5° for flap deflections of 20°
- 8° for flap deflections of 48°
-
APU
BLEED
APU bleed valve in not closed and any 1 of the 3 throttles is >54° PLA
APU bleed switch is in OFF and APU bleed air valve is open
APU shutdown and bleed air vlave is open
-
BLEED
OVHT
Overheat detection is >310°C or 275°C. E.I.E.D. may display mssg flag indicating faulty bleed area
-
L.PITOT R.PITOT
For associated LH or RH circuit
No electrical current for pitot heat or static probe heating
Heating system monitoring circuit is failed
-
AIL ZERO
Emergency aileron actuator is not set to zero: (It is out of the +/- 30 minute range)
-
Q-UNIT
Failure of ARTHUR Q monitoring
Discrepancy between speed information from air data computer & from aileron and/or elevator Arthur Q
Deviation of +/- 30 kt. Up to IAS = 250 kt. Deviation of +/-50 kt. at 370 kt.
-
AP TRIM
AP coupler trim circuit failed (monitoring of electrical pulses sent to horizontal stab actuator by AP coupler)
-
MISTRIM
Horizontal stabilizer does not move, although commanded to do so by the autopilot
-
GEN 1 GEN 2 GEN 3
Generator mounted on engine #1, #2, or #3 is not connected to main bus bar (associated reverse current relay open)
-
BAT 1 BAT 2
Main bus bars are no longer suplied by batteries (associated contactor open)
-
BUS TIED
Bus-tied relay closed and 225 amp current limiter is good. Means left & right main busses are tied
-
ENG 1
COMPUTER
ENG 2
COMPUTER
ENG 3
COMPUTER
Computer of associated engine is off. Or
Computer has failed (internal failure or electrical power supply failure or incorrect data has been processed to the computer)
-
FUEL 1 FUEL 2 FUEL 3
Fuel booster pump pressure < 5.0 - 6.0 psig (345 - 415 reletive mbar)
-
FUELING
Any 1 of the 3 air-vent valves (feeder tank or wing tank) is not closed or
Defueling valve is not closed or
Pressure refueling access door is not closed or
Gravity fueling control switch is not in the OFF position
-
LO FUEL
Fuel level in any 1 of the 3 feeder tanks < 250-300 lb for a minimum of 15 +/- 3 seconds
-
HYD TK
PRESS
Hydraulic tank pressure is < 16 psia in either one or both hydraulic reservoirs
-
BRAKE
ACCU
Parking brake accumulator hydraulic pressure is < 1200 psi of trapped hydraulic fluid
-
ST PUMP
#2
Illuminates when either of the following occurs:
- Standby pump is running continuously for longer than 60 seconds
- Standby pump selector handle is in ground mode
-
APU GEN
APU generator reverse-current relay has opened
-
NOSE FAN
FAIL
Nose cone fan failure after a 15 second time delay
-
HYDR #1
PUMP 1
Hydraulic system #1 pressure is < 1,500 psi downstream from hydraulic pump 1
-
HYDR #1
PUMP 2
Hydraulic system #1 pressure is < 1,500 psi downstream from hydraulic pump 2
-
HYDR #2
PUMP 3
Hydraulic system #2 pressure is < 1,500 psi downstream from hydraulic pump 3
|
|