CARGO EXTG 1/2
inner bottle pres. falls to 310-260 psi (up to 15 min)
L/R PITOT
power is lost
115 gen bus
triggers cwp light
STBY PITOT
power is lost or switch is off
triggers cwp light
L/R ALPHA
power is lost
triggers cwp light
OAT
power is lost
triggers cwp light
L/R SIDE/FRONT
steady
-power loss
-over temp sensor
-controller failure
intermittantly
-temp sensor fails
L/R PROP
fault detected
triggers cwp
L/R INTAKE
steady
-heat inop
-unpowered (1 or more phases)
-under temp sensor below +10c
intermittantly
-cycling on over temp sensor 40-125c
triggers cwp
L/R AIR VALVE
valve/switch disagreement
triggers cwp
L/R AC GEN
bus is unpowered
triggers cwp
DE-ICE OVER TEMP
bleed air >150c
triggers cwp
TIMER
no pres downstream w/ valve open
timer gives no inflation signal
boots not cycling
pres remains in boot
power to timer lost