Atmospheric pressure at sea level
-
Altitude pressure drop
0.5 psi (3.5 kPa) per 1000 feet
-
1 cubic foot of water exerts:
0.434 psi
-
0.1m x 0.1m x 0.1m of water is:
- 1 liter of volume,
- 1 kilogram of mass,
- 1 kPa of pressure
-
1 foot square column of water needs to be this high to exert 1 psi:
2.304 feet
-
The weight of 1 cubic foot of water
62.5 pounds
-
Water distribution lines
- Primary feeders - 16"
- Secondary feeders - 12"
- Distributors - 8"
- Hydrant supplies: Residential - 6"
- Commercial - 8"
-
Class A foam percentages
0.2-1.0%
- 0.2-0.5 - fire attack; CAFS
- 0.5-1.0 - exposure protection
- 0.3-0.7 - air aspirating foam nozzles
-
Three factors that influence centrifugal pumps
- Amount of water being discharged
- Speed of the impeller
- Pressure of water entering the pump
-
ARAFFF
Alcohol resistant aqueous film forming foam
-
Master Stream Flows and Friction Losses (per 100' of 21/2")
- 11/4" - 400 gpm, 36 psi
- 11/2" - 600 gpm, 78 psi
- 13/4" - 800 gpm, 136 psi
- 17/8" - 900 gpm, 171 psi
- 2" - 1,000 gpm, 210 psi
-
11/4" Master stream
- 80 psi
- 400 gpm
- FL = 36 psi per 100' of 21/2" line
-
11/2" Master Stream
- 80 psi
- 600 gpm
- FL = 78 psi per 100' of 21/2" line
-
13/4" Master stream
- 80 psi
- 800 gpm
- FL = 136 psi per 100' of 21/2" line
-
17/8" Master stream
- 80 psi
- 900 gpm
- FL = 171 psi per 100' of 21/2" line
-
2" Master stream
- 80 psi
- 1,000 gpm
- FL = 210 psi per 100' of 21/2" line
-
Safest water flow rule
- 75/80/80
-
75o elevation - 80% extension
- 80 psi nozzle pressure on smooth bore
-
Water weight on structure
250 gpm = 1 ton per minute
-
NPDP
- Net pump discharge pressure
- work pump has to do on water
Hydrant at 100 psi with PDP of 150 psi = NPDP of 50 psi
-
Idling Diesels
Burn 1/2 gallon diesel per hour
Cause carbon build-up on injectors, valves, pistons, and valve seats; damage turbo shaft
-
SAE
Society of Automotive Engineers
SAE number indicates viscosity
-
Aerial apparatus categories
- Aerial ladders
- Elevating platforms
- Water towers
-
IFSTA Formula for Friction Loss
FL = CQ 2L
- C = 13/4" = 15.5
- 21/2" = 2
- 5" = 0.08
-
Dual Pumping
One hydrant hooked to pumper, excess hydrant pressure flows through 1st pumper to 2nd pumper
-
Handline Flows and Friction Losses (per 100' of 13/4" unless otherwise noted)
- TFT - 170 gpm, 35 psi
- Control Nozzle on 21/2" - 250 gpm, 15 psi
- 3/4" - 120 gpm, 20 psi
- 7/8" - 160 gpm, 30 psi
- 15/16" - 180 gpm, 40 psi
- 1" - 200 gpm, 50 psi
- 11/8" (21/2" hose) - 250 gpm, 15 psi
- 11/4" (21/2" hose) - 325 gpm, 25 psi
-
1" Handline
- 50 psi
- 200 gpm
- FL = 50 psi per 100' of 1 3/4" hose
-
11/8" Handline
- 50 psi
- 250 gpm
- FL = 15 psi per 100' of 21/2" hose
-
11/4" Handline
- 50 psi
- 325 gpm
- FL = 25 psi per 100' of 21/2" hose
-
Apparatus Tests
- Accelerate to 35 mph in 25 seconds
- Minimum top speed 50 mph
- Stop from 20 mph in 35'
-
Hydrostatic Test
Pumps 250 psi for 3 min
-
Water Tower Flows
1,000 to 5,000 gpm
-
Aerial Roof
6' above roof line
-
Power Lines
Stay away minimum of 10'
-
Collapse Zone
Height of Building x 1.5
-
13/4" Control Nozzle
- 100 psi
- 170 gpm
- FL = 35 psi per 100' of 13/4" hose
-
21/2" Control Nozzle
- 100 psi
- 250 gpm
- FL = 15 psi per 100' of 21/2" hose
-
NFPA 1451
Standard for Fire Service Vehicle Operations Training Program
-
NFPA 1500
Standard on Fire Department Occupational Safety and Health Program
-
NFPA 1001
Standard for Firefighter Professional Qualifications
-
NFPA 1906
Standard for Wildland Fire Apparatus
-
NFPA 1582
Standard on Medical Requirements for Firefighters
-
NFPA 1914
Standard for Testing Fire Department Aerial Devices
-
NFPA 1901
Standard for Automotive Fire Apparatus. Requires minimum pump capacity of 750 gpm.
-
NFPA 1002
Standard for Professional ADO Qualifications (includes preventative maintenance and inspections)
-
Quint
- Apparatus equipped with:
- 1. Pump > 1,000 gpm
- 2. Tank > 300 gallons
- 3. Ground Ladders > 85'
- 4. Hose > 800' of 21/2" Supply + 400' of 13/4" Attack
- 5. Aerial Device
-
Aerial Hydraulics
3,500 psi positive displacement rotary vane or rotary gear
-
Valve Controls
- Manual
- Mechanical
- Electrical
- Hydraulic
or combination of these
-
PTO Activation Switches
- Pneumatic - 50 - 140 psi air
- Electric
- Hydraulic
or combination of these
-
Foam Expansion
- Low: 0 - 20:1
- Med: 20:1 - 200:1
- High: 200:1 - 1,000:1
-
Foam Tetrahedron
- Foam concentrate
- Water
- Air
- Mechanical agitation
-
Class A Foam Percentages
- 0.2 - 0.5% = fire attack/overhaul
- 0.5 - 1.0% = exposure protection
- 0.3 - 0.7% = any application with air aspirating nozzles
- 0.2 - 0.5% = CAFS
-
-
Extrication Pump Hose Length
Not capable of supplying full power when hose exceeds 100'
-
Apparatus Collision Categories
- Improper Backing
- Reckless Driving (Public)
- Excessive Speed
- Lack of Driving Skill
- Poor Apparatus Design or Maintenance
-
Apparatus Control Factors
- Aim high in steering
- Get "big picture"
- Keep eyes moving
- Leave yourself an "out"
- Make sure others see or hear you
-
Auxilliary Braking Systems
- Front brake limiting
- Interaxle differential lock
- ABS Anti-lock Braking System
- ATC Automatic Traction Control
-
Offensive Aerial Positioning
Front of involved portion of structure
-
Counter Balance Valve
Prevents unintentional or undesireable operation
-
Selector Valve
3-way valve directs fluid to stabilizers or Aerial, but not both at the same time
-
Ladder Elevation
70o to 80o when possible
-
Longitudinal Uneveness
6 - 14%
Aerial should not be extended or retracted over side of apparatus
-
Correction of Lateral Unevenness
Achieved on grades up to 5 - 6%
-
Water Weights
- 62.5 lbs per ft3
- 8.33 lbs per gallon
- Column of water 2.304' tall = 1 psi
- 1 ft3 of water = 0.434 psi, 7.5 gallons
-
Portable Generators
5,000 Watts
-
Vehicle Mounted Generators
12,000 Watts
Common on Aerials
-
Aerial Device Loads
- Perpendicular
- Lateral (Bad)
-
Handline Flow Limit
350 gpm
-
Master Stream Flow
350 gpm or greater
-
Fire Stream Velocities
60-120 ft/sec at 25-100 psi
-
Master Stream Pressure
80 psi
-
Solid Stream Nozzle Reaction Formula
NR = 1.57 x d2 x NP
-
Fog Stream Nozzle Reaction Formula
NR = 0.0505 x Q x
-
Determining PDP
PDP = NP + TPL
-
NFPA 1931
Standard for manufacturer's design of Fire Department ground ladders
-
Minimum Rated Capacity of Mobile Foam Firefighting Apparatus
750 gpm
-
Turbidity
The amount of particulate matter suspended in water
-
Residual Pressure
An indication of how much more water is available in the system
-
NFPA 291
Recommended Practice for Fire Flow testing and marking of hydrants
-
Portable Pumps
Can deliver up to 500 gpm
-
Air Brake Check "COLA"
- C - Air Compressor cuts in no lower than 85 psi
- O - Air compressor cuts Out in high idle between 110-120 psi
- L - Low pressure warning kicks on, parking brake kicks in around 40 psi
- A - Air Leakage rate < 3 psi per min.
-
Flow Ratings
- 100% volume @ 150 psi
- 70% volume @ 200 psi
- 50% volume @ 250 psi
-
13/4" Hose with Fog Nozzle Standard Flow
150 gpm
-
13/4" Hose with 15/16" - 1" Nozzle Standard Flow
180 -200 gpm
-
200' Rule for 13/4" Hose
The PDP is equal in to the flow in gallons per minute from the nozzle.
-
Drop 12 Method
- Subtract 12 from the first two digits of the flow. That will give friction loss for 100' of 21/2" hose.
- For flows above 350, drop 12 and then add back in the first digit of the flow; i.e., 350-> 35 - 12 = 23 + 3 = 26
-
14.7 PSI
- Atmospheric Pressure at sea level
- 30" of mercury
- 33.9' of water
-
Nozzle Reaction
1.5 x D2 x NP
-
Velocity of Fire Stream in FPS
12.1 x
-
Standard Sources of Friction Loss
- 5 psi per floor/10' of elevation (do not count ground floor)
- 25 psi for Standpipe
- 25 psi for prepiped Aerial
- 10 psi for Wye/Siamese
-
Available Flow from Hydrants
- 10% drop = 3 more like volumes
- 15% drop = 2 more like volumes
- 25% drop = 1 more like volume
-
PCFD Apparatus Placement SOG
- Use "Key Positions," including:
- Aerial placement in relation to overhead obstructions
- Engine placement in relation to water supply
- Priorities: Safety, Incident Objectives, Incident Expansion.
- Level I Staging for 2 or more like vehicles
- Level II Staging for multiple alarms or mutual aid
-
PCFD Accident Involvement SOG
- Check for injuries
- Report to law enforcement and BC if injuries or outside property damage are present
- Report to BC if on emergency response and no injuries or outside property damage are present
- Remain on-scene if not on emergency response and injuries or outside property damage are present
-
NWCG Structural Engine Typing
- Type 1:
- 1000 gpm pump at 150 psi, 400+ gallon tank, 1200' of 21/2", 400' of 11/2", 48' of ladders, 500 gpm master stream, 4 Personnel
- Type 2:
- 250 gpm pump at 150 psi, 400+ gallon tank, 1000' of 21/2", 500' of 11/2", 48' of ladders,
- 3 Personnel
-
NWCG Wildland Engine Typing
- Type 3:
- 150 gpm @ 250 psi, 500+ gallons, 500' of 11/2", 500' of 1", 3 personnel
- Type 4:
- 50 gpm @ 100 psi, 750+ gallons, 300' of 11/2", 300' of 1", 2 personnel
- Type 5:
- 50 gpm @ 100 psi, 400-750 gallons, 300' of 11/2", 300' of 1", 2 personnel
- Type 6:
- 30 gpm @ 100 psi, 150-400 gallons, 300' of 11/2", 300' of 1", 2 personnel
- Type 7:
- 10 gpm @ 100 psi, 50-200 gallons, 200' of 1", 2 personnel
-
FEMA Engine Typing
(ESF 4)
- Type I:
- 1000 gpm, 400 gal., 1200' of 2.5", 400' of 1.5", 200' of 1", 4 personnel
- Type II:
- 500 gpm, 400 gal., 1000' of 2.5", 500' of 1.5", 300' of 1", 3 personnel
- Type III:
- 120 gpm, 500 gal., 1000' of 1.5", 800' of 1", 3 personnel
- Type IV:
- 70 gpm, 750 gal., 300' of 1.5", 300' of 1", 2 personnel
- Type V:
- 50 gpm, 500 gal., 300' of 1.5", 300' of 1", 2 personnel
- Type VI:
- 50 gpm, 200 gal., 300' of 1.5", 300' of 1", 2 personnel
- Type VII:
- 50 gpm, 125 gal., 200' of 1.5", 200' of 1", 2 personnel
-
NWCG Water Tender Typing
- Type 1:
- 5000 gal., 300 gpm, 30 min refill time
- Type 2:
- 2500 gal., 200 gpm, 20 min refill time
- Type 3:
- 1000 gal., 200 gpm, 15 min refill time
-
FEMA Water Tender Typing
(ESF 4)
- Type I:
- 2000 gal., 300 gpm
- Type II:
- 1000 gal., 120 gpm
- Type III:
- 1000 gal., 50 gpm
|
|