-
Lab Value for CVP
2-6 mmHg
-
Lab Value for RAP
2-6 mmHg
-
Lab Value for RVP
15-25 / 0-5 mmHg
-
Lab Value for PAP
15-25 / 8-15 mmHg
-
Lab Value for PAWP
8-12 mmHg
-
Lab Value for PCWP
8-12 mmHg
-
Lab Value for CO
408 L/min
-
Lab Value for CI
2.5-4.2 L/min
-
Lab Value for SV
60-135 mL
-
Lab Value for SI
25-45 Ml/m2
-
Lab Value for PVR
50-250 dyn
-
Lab Value for SVR
800-1200 dyn
-
Lab Value for LAP
4-12 mmHg
-
PAS correlates to what part of the ECG
Just after the QRS correlates to what phase of PA waveform
-
Pulmonary catheter lines
- Single thin black line is 10cm
- Single thick black line is 50cm
- Double thick black line is 100cm
-
PA catheter insertion sites
- Right internal jugular
- Left subclavian
- Femoral veins
-
PAC positions
- RA--25-30 cm (proximal port/lumen)
- RV--35-45 cm
- PA--50-55 cm (distal port/lumen)
-
Use of PAC
- Assessment of volume status where CVP is unreliable
- Sampling of mixed venous blood to calculate shunt fraction
- Measurement of CO using thermodilation
- Derivaion of other cardiavascular indices such as PVR, o2 delivery and uptake
-
Complications of insertion
- Valve rupture
- Pulmonary embolism
- Pulmonary infarct
- Pulmonary artery rupture and hemorrhage
- Dysrhythmias
- Infection
- Pneumothorax
- Bleeding around site
- Balloon rupture
- Knotting of catheter in RV
-
The PAWP should always be lower than
The PAP should always be higher than
-
Clues for determining RV waveform
- Waves are taller in appearance than PAs
- Waveform is symmetrical in shape with no dicrotic notch
- Closer to the QRS than PAP
- Inflation of the wedge ballon fails to dampen waveform
-
RA systole wave
a wave is the
-
RA diastole wave
x wave descent is
-
Tricuspid valve closure wave
c wave is
-
RA filling/tricuspid valve closed wave
v wave is
-
RA emptying at opening of tricuspid valve/onset of right ventricle diastole
y wave descent is
-
Causes of decreased CVP/RAP (2-6 mmHG)
- Hypovolemia
- Vasodilation
- Decreased venous return (preload)
- Negative pressure ventilation
-
Causes of increased CVP/RAP (2-6 mmHg)
- Hypervolemia
- Right-sided heart failure
- Cardiac tamponade
- Positive pressure ventilation
- COPD
- Pulmonary HTN
- Pulmonary embolus
- Pulmonic stenosis
- Tricuspid stenosis
- Tricuspid regurgitation
-
Causes of increased RVP (15-25 / 0-5 mmHg)
- Pulmonary HTN caused by left heart failure
- COPD
- Pulmonary embolus
-
Causes of increased PAP (15-25 / 8-15 mmHg)
- Fluid overload
- Atrial or Ventricular defects
- Pulmonary diseases
- LV failure
- Mitral stenosis
- Mitral regurgitation
-
Causes of decreased PAWP/PCWP (8-12 mmHg)
- Hypovolemia
- Venodilating drugs
-
Causes of increased PAWP/PCWP (8-12 mmHg)
- LV failure
- Constrictive pericarditis
- Mitral stenosis
- Mitral regurgitation
- Fluid overload
- Renal failure
-
Causes of increased PVR (50-250 dys)
Pulmonary disease
-
Causes of decreased SVR (800-2500 dys)
- Septic shock
- Anaphylactic shock
- Neurogenic shock
- Vasodilators
-
Causes of increased SVR (800 -2500 mmHg)
- Hypovolemic shock
- Cardiogenic shock
- RV MI
- Aortic stenosis
- Vasoconstrictors
-
Rolling PAWP waveforms are indicative of
Increased PAWP (pulmonary congestion) readings have a waveforms that is
-
Phlebostatic axis is located at
The junction of the vena cava and the right atrium is known as the
-
Cather whip is noted by the waveform being
Exaggerated wave form, caused by HTN, are known as
-
Overdampened waveforms have a one line flush test and are caused by
Kinked catheter tips, tip against a wall, increased pressure in the bag, will all lead to
-
Underdampened waveforms show many lines of oscillation and are cause by
Air in the system, loose connections, low pressure in the bag, and altitude changes all lead to
-
Hypovolemic shock lab values present as (4 values)
CVP low, CI low, PAWP low, SVR high
-
Cardiogenic shock lab values present as (4 values)
CVP high, CI low, PAWP high, SVR high
-
RVMI lab values present as (4 values)
CVP high, CI low, PAWP low, SVR high
-
Septic shock lab values present as (3 values)
CI low, HR normal or slow, SVR low
-
Anaphylactic shock lab values present as (3 values)
CI low, HR fast, SVR low
-
Coronary Perfusion Pressure (CPP, 50-60 mmHg) formula is
DBP-PAWP (50-60 mmHg)
-
Mean Arterial Pressure (80-100 mmHg) formula is
(2xDBP+SBP)/3
-
CVP/RAP reflects
Right atrial pressure preload lab value is measured by
-
PAP reflects
Left and Right sided heart pressure lab value is measured by
-
PAWP reflects
Pressure on the left side of the heart, preload, is measured by
-
-
CI definition is
Based on BSA and is more accurate than CI, this assesses blood flow
-
SV is
Amount of blood ejected with each heartbeat from the ventricles during systole
-
SI is
Components of SV are preload, afterload, and contractility
-
PVR is
Measurement of afterload in right ventricle is
-
SVR is
measurement of afterload in left ventricle
-
LAP reflects
Filling pressure in left ventricle
-
Drug of choice for distributive shock is
Levophed
-
Levophed, 2-12 ug/min, acts by
increasing coronary blood flow with both alpha and beta effects
-
Drugs that decrease preload (3)
-
Drugs that increase preload (2)
-
Drugs that decrease afterload (5)
- Nipride
- Corlopram
- Calcium channel blockers
- Dobutrex
- Xatecor
-
Drugs that increase afterload (4)
- Dopamine
- Neosynephrine
- Levophed
- Epinephrine
-
Isovolmetric contraction is defined as
The period when all four valves are closed is called
-
Spontaneous breathing causes a drop in vascular pressures
Immediately before inspiration, and gradually rising until end expiration
-
Hemodynamic pressure should be evaluated
At the end of expiration, read
-
The z point is used to measure atrial pressure and it is
A line drawn from the end of the QRS to the hemodynamic tracing, and is delayed by .08-.12 second for PAWP
|
|